ASFIFF12 High Speed
vacon • 13
24-hour s358 (0)40 837 1150 • Email: [email protected]
4.6
Prohibit frequency parameters (Control keypad: Menu M2
Æ
G2.5)
Code
Parameter
Min
Max
Unit
Default
Cust
ID
Note
P2.5.1
P2.5.2
Hz
509
P2.5.2
Hz
510
P2.5.3
0,1 10,0 1,0
518
Table 4-9. Prohibit frequency parameters, G2.5
4.7
Motor control parameters (Control keypad: Menu M2
Æ
G2.6)
Code
Parameter
Min
Max
Unit
Default
Cust
ID
Note
NXS:
0
=Frequency control
1
=Speed control
P2.6.1
1/4
0
600
Additionally for NXP:
2
=Not used
3
=Closed loop speed ctrl
4
=Closed loop torque ctrl
P2.6.2
0 1 0
109
0
=Not used
1
=Automatic torque boost
P2.6.3
0 3 0
108
0
=Linear
1
=Squared
2
=Programmable
3
=Linear with flux optim.
P2.6.4
Hz
602
P2.6.5
10,00
200,00 % 100,00
603
n% x U
nmot
P2.6.6
P2.6.4
Hz
604
P2.6.7
0,00 100,00 % 100,00
605
n% x U
nmot
Parameter max. value = P
2.6.5
P2.6.8
0,00 40,00 % Varies
606
n% x U
nmot
P2.6.9
1,0 Varies kHz Varies
601
See Table 5-6 for exact
values
P2.6.10
0 2 1
607
0
=Not used
1
=Used (no ramping)
2
=Used (ramping)
P2.6.11
0 1 1
608
0
=Not used
1
=Used
P2.6.12
0,00 100,00 % 0,00 620
P2.6.13
631
0
=No action
1
=Identification w/o run
2
=Identification with run
P2.6.14
Modulator
Type
0 1 0
1518
0
= Default PWM
1
= Space Vector PWM
.
Table 4-10. Motor control parameters, G2.6