114
• VACON®
apfiff09 marine
Local contacts: http://drives.danfoss.com/danfoss-drives/local-contacts/
7.2.2 Constant Reference
P2.2.7.1 Jogging speed reference
ID124
“Jog Speed Ref”
Defines the jogging speed reference when activated by a digital input. This reference will
follow the reverse command if given. Jogging speed has a higher priority than preset
speed references.
Related parameters
-
Digital Input P2.4.2.16 Jogging Speed
P2.2.7.2 Preset speed 1
ID105
“Preset Speed 1”
P2.2.7.3
Preset speed 2
ID106
“Preset Speed 2”
P2.2.7.4
Preset speed 3
ID126
“Preset Speed 3”
P2.2.7.5
Preset speed 4
ID127
“Preset Speed 4”
P2.2.7.6
Preset speed 5
ID128
“Preset Speed 5”
P2.2.7.7
Preset speed 6
ID129
“Preset Speed 6”
P2.2.7.8
Preset speed 7
ID130
“Preset Speed 7”
Parameter values define the Preset speeds references activated by digital inputs. These
references will follow reverse command if given.
Speed
Digital Input
Preset speed 1
Digital Input
Preset speed 2
Digital Input
Preset speed 3
Basic speed
0
0
0
Preset Speed
1
1
0
0
Preset Speed
2
0
1
0
Preset Speed
3
1
1
0
Preset Speed
4
0
0
1
Preset Speed
5
1
0
1
Preset Speed
6
0
1
1
Preset Speed
7
1
1
1
Table 7-1. Preset speeds 1 to 7
Related parameters
Digital inputs P2.4.2.5-7 Preset Speed 1-3
Содержание apfiff09 marine
Страница 1: ...vacon nx ac drives apfiff09 marine application manual ...
Страница 2: ......
Страница 310: ......