2. Remove power head and place in an upside down position.
3. Install the cartridge filter over the filter cage with the flat end of the filter
towards the vacuum cleaner power head. Carefully push filter in until it
stops against the power head. (fig.2 & 3)
4. Place filter retainer on top of cartridge filter over the raise lip and tighten
down by turning retainer clockwise, do not over tighten. (fig. 4 & 5)
Removing and Cleaning Filter
1. Unlock and remove the filter retainer by tuning retainer handle counter
clockwise.
2. Carefully hold and pull the cartridge filter up for removal. (fig.6)
3. Clean the cartridge filter by gently tapping or brushing dirt off. Cleaning
should not be done indoors in living areas. For optimal performance a
new filter is recommended.
4. Install cleaned or new filter into place as instructed above in steps 2 and
3 of Installing Cartridge Filter.
5. Wet filters should be removed and allowed to air dry for 24 hours before
installing onto the filter cage.
6. Carefully remove the pre-filter from the container and clean the dirt from
the filter by gently tapping or brushing dirt off.
I
NSTALLING & CLEANING FOAM FILTER
Installing Foam Filter
1. Verify that the power cord is disconnected from the power socket. (fig.1)
2. Remove power head and place in an upside down position. Follow
instructions to remove cartridge filter.
3. Carefully slide foam filter down over the filter cage making sure the
whole cage is covered. (fig.2 & 3)
4. Replace the power head on to the container.
Cleaning Foam Filter
1. With the removed power head in the upside down position, carefully
remove foam filter. (fig.4)
2. Use a mild soap and water solution to wash foam filter and rinse with
clean water. (fig.5)
3. Allow filter to air dry before installing and using again.
T
ROUBLESHOOTING
WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK-UNPLUG
BEFORE TROUBLESHOOTING.
Symptom
Possible Causes
Corrective Action
Vacuum
cleaner will not
operate.
1) No power supply.
1) Check power supply –
cord, breakers, fuses.
2) Faulty power cord.
2) Unplug and check the
power cord. If damaged,
have it repaired by a
professional.
3) Container full.
3) Empty container.
Dust comes
out from motor
cover.
1) The cartridge filter or
dust bag is missing or
damaged.
1) Attach or replace
cartridge filter or dust bag.
Reduced
efficiency and
motor/speed
vibration.
1) There is a blockage
in the nozzle or hose, or
the container inlet. Or
dust filter blocked by fine
dust.
1) Check nozzle, hose
and container inlets for
blockage. Take off the filter
and clean it. Or install new
cartridge filter.