13
TROUBLESHOOTING
WARNING:
TO REDUCE THE RISK OF ELECTRIC SHOCK, UNPLUG BEFORE
TROUBLESHOOTING.
Cleaning Performance
Vacmaster vacuum cleaners are tested for endurance. If your motor is operating, then the most
likely cause for a loss in suction is a blockage or an opening in the vacuum.
To maintain a high cleaning performance from your machine, it is important to replace or clean
reusable cloth filters as necessary. A performance drop with clean filters can only be caused by a
blockage in the tools or the hose.
PROBLEM
POSSIBLE CAUSE
SOLUTION
The appliance does
not work.
No power.
Check the power supply and fuse.
Functional fault in the power
cord, switch, or motor.
Have the damaged part checked by
qualified personnel or contact the after
sales helpline.
Dust is escaping from
the motor cover.
The reusable cloth filter is
missing or damaged.
Put in a reusable cloth filter or replace
it.
Misuse the reusable cloth filter
when wet vacuuming, causing
the damage of reusable cloth
filter.
Replace the damaged reusable
cloth filter with a new one when dry
vacuuming.
Misuse the foam filter when
dry vacuuming.
Replace the foam filter with the
reusable cloth filter.
Low suction power
and high operating
noise / vibrations.
Suction nozzle, hose, or tank
inlet is blocked.
Check the suction nozzle, hose, and
tank inlet for obstructions.
Reusable cloth filter is
blocked.
Remove the reusable cloth filter and
clean.
Float valve has closed.
Empty the container of any liquid
waste and ensure the float value
located underneath the filter is able to
move freely.