![Vacmaster VP215 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/vacmaster/vp215/vp215_user-manual_3126455009.webp)
www.VacMasterFresh.com • 800-821-7849
8
HOW TO
Set Up - Adjusting the VP215 Timing Controls
Vacuum Time:
To increase or decrease the vacuum time, press the
SET button until VACUUM is illuminated and then use the UP/DOWN
buttons to adjust the vacuum time accordingly. The time setting will
display on the LED Screen on the control panel.
Note: Filler plates can be used to reduce the vacuum time required. Place the
filler plates inside the chamber as desired. Filler plates occupy space, leaving
less air to be removed from the chamber. If you require more space inside the
chamber, remove the filler plates to accommodate your product.
Sealing Time:
To increase or decrease the sealing time, press the
SET button until SEALING is illuminated and then use the UP/DOWN
buttons to adjust the sealing time to accommodate your application.
It is recommended that you make adjustments in 0.1 second
increments to avoid melting the pouch.
Note: For thicker pouches, you should increase the seal time in 0.1 second
increments until the pouch seals completely. In addition, for thinner pouches, you
should decrease the seal time in 0.1 second increments to avoid over-sealing the
pouch.
Cooling Time:
To increase or decrease the cooling time, press
the SET button until COOLING is illuminated and then use the UP/
DOWN buttons to adjust the cooling time accordingly.
Note: The VP215 settings will always default to the most recently used settings on
the machine.
To prolong the life of your seal bar, set the cooling time to twice
the sealing time.
TIP: