background image

12

IMPORTANT! 

When vacuuming large quantities of liquids, do not immerse the nozzle completely 

in the liquid; leave a gap at the tip of the nozzle opening to allow air inflow. The machine is fitted 

with a float valve that stops the suction action when the collection tank reaches its maximum 

capacity. You will notice an increase in motor speed. When this happens, turn off the machine, 

disconnect from power supply, and drain the liquid. To continue vacuuming, replace the drain 

cap. After wet vacuuming, turn the machine off and remove plug from power supply. Empty the 

collection tank, clean and dry the inside and outside before storage. 

REMEMBER! 

The foam wet filter must be removed after wet vacuuming and the cartridge filter 

must be installed before dry vacuuming again.

BLOWER OPERATION

This Wet/Dry Vacuum has blowing capabilities. To use the blower feature follow the instructions 

listed.

1.  Verify that the power cord is disconnected from the outlet (Fig. 1).

2.  Make sure the collection tank is empty before using as a blower. Clear all dirt and debris from 

the hose and collection tank.

3.  Remove hose from the vacuum port.

4.  Insert the larger end of the hose into the blower port on the side of the power head and lock into 

place (Fig. 2).

5.  Choose the desired accessory and insert onto the end of the hose (Fig. 3).

6.  Verify that the on/off switch is in the ‘O’ OFF position before plugging the power cord into the 

outlet. Plug the power cord into the outlet (Fig. 4 & 5).

7.  Before turning on the vacuum, firmly hold the loose end of the hose. Turn the motor on by 

flipping the switch to the ‘I’ ON position (Fig. 6).

8.  Once you have completed blowing, flip the on/off switch to the 'O' OFF position and unplug the 

power cord from the outlet.

WARNING:

 ALWAYS WEAR SAFETY GOGGLES COMPLYING WITH ANSI Z87.1 

(OR IN CANADA, CSAZ94.3) BEFORE USING BLOWER.

WARNING: 

WEAR A DUST MASK IF BLOWING CREATES DUST THAT MIGHT 

BE INHALED. 

CAUTION:

 KEEP BYSTANDERS CLEAR FROM BLOWING DEBRIS.  

6

4

2

1

5

3

Содержание VDK611PF 0201

Страница 1: ...fore use Keep this manual for future reference Operator s Manual Wet Dry Vacuum 6 Gallon Model No VDK611PF 0201 Replacement Filters Accessories available at Vacmaster com Suzhou Cleva Electric Appliance Co Ltd NO 8 Ting Rong Street 215122 Suzhou China ...

Страница 2: ...producing a high quality durable product This Vacmaster product carries a limited three 3 year warranty against defects in workmanship and materials from date of purchase under normal household use If product is to be used for commercial industrial or rental use a 90 day limited warranty will apply Please keep your receipt as proof of purchase This warranty gives you specific legal rights which ma...

Страница 3: ...ashes Do not expose to rain Store indoors If vacuum is not working as it should has been dropped damaged left outdoors or dropped into water return it to a service center Do not unplug by pulling on cord To unplug grasp the plug not the cord Do not use with damaged cord or plug Do not pull or carry by cord use cord as a handle close a door on cord or pull cord around sharp edges or corners Keep co...

Страница 4: ...NUAL DO NOT RUN UNATTENDED DO NOT PICK UP HOT ASHES COALS TOXIC FLAMMABLE OR OTHER HAZARDOUS MATERIALS DO NOT USE AROUND EXPLOSIVE LIQUIDS OR VAPORS CAUTION DO NOT VACUUM DRYWALL DUST OR FIREPLACE SOOT OR ASH WITH STANDARD WET DRY FILTER THIS TYPE OF DUST IS VERY FINE WHICH MAY NOT BE CAPTURED BY THE FILTER AND CAUSE DAMAGE TO MOTOR WHEN VACUUMING FINE DUST USE A FINE DUST FILTER WARNING SERVICING...

Страница 5: ...ry NOTICE Without Safety Alert Symbol Indicates a situation that may result in property damage SYMBOLS EXTENSION CORDS When using an extension cord with your Wet Dry Vacuum refer to the following table to determine the required A W G wire size Before using the cleaner make sure the power cord and extension cord are in good working condition Make repairs or replacements before using the vacuum clea...

Страница 6: ...H I J K L M N O P Vacuum Assembly Handle Hose Extension Wands Floor Brush Squeegee Nozzle Utility Nozzle Crevice Tool Dust Bag Cartridge Filter Filter Retainer Foam Wet Filter Caster Foot Assembly 6 Screws Bag Hose Storage Racks Drain Cap Operator s Manual NOTE The hose and accessories for this vacuum are 1 7 8 3 8 cm diameter Power Cord Storage Collection Tank Hose Storage Rack Handle Filter Clea...

Страница 7: ...rews Fig 5 6 Position the hose storage rack as illustrated Squeeze the open sides of the hose storage rack inward Insert the hose storage rack into the channel on the front side of the power head just above the top edge of the tank Verify that the rack is secured in place as shown in Fig 8 Then squeeze in the other hose storage rack and insert it into the corresponding channel making sure it is se...

Страница 8: ...lection tank aligning the top section with the latches and snap into place Fig 15 12 Fit the drain cap onto the drain port and turn clockwise to secure Fig 16 13 Insert the larger end of the hose into the vacuum port of the collection tank and lock into place Fig 17 14 Choose the desired accessory and insert onto the end of the hose or extension wand Fig 18 POLARIZED PLUG To reduce the risk of ele...

Страница 9: ...O A POWER OUTLET MAKE SURE THE PLUG IS DISCONNECTED BEFORE CHANGING THE FILTERS DRY VACUUMING CAUTION DO NOT VACUUM DRYWALL DUST FIREPLACE SOOT OR ASH WITH STANDARD WET DRY FILTER THIS IS A VERY FINE DUST WHICH WILL NOT BE CAPTURED BY THE FILTER AND MAY CAUSE DAMAGE TO THE MOTOR WHEN VACUUMING FINE DUST USE A FINE DUST FILTER 1 Verify that the power cord is disconnected from the outlet Fig 1 2 You...

Страница 10: ...ing the switch to the I ON position and begin vacuuming Fig 10 10 Once you have completed vacuuming flip the switch to the O OFF position and unplug the power cord from the outlet O OFF I ON DO NOT USE THE CARTRIDGE FILTER FOR LIQUID VACUUMING DO NOT USE THE DUST BAG FOR LIQUID VACUUMING FILTER CLEANING OPERATION IMPORANT Only perform the filter cleaning operation when the cartridge filter is inst...

Страница 11: ...st and dirt Fig 1 2 Remove the cartridge filter then carefully install the foam wet filter over the filter cage and place the power head back on the collection tank Fig 2 For foam wet filter installation instructions see page 15 DO NOT USE THE CARTRIDGE FILTER FOR LIQUID VACUUMING DO NOT USE THE DUST BAG FOR LIQUID VACUUMING OPERATING INSTRUCTIONS WET VACUUMING 3 Choose the desired accessory and i...

Страница 12: ...tions listed 1 Verify that the power cord is disconnected from the outlet Fig 1 2 Make sure the collection tank is empty before using as a blower Clear all dirt and debris from the hose and collection tank 3 Remove hose from the vacuum port 4 Insert the larger end of the hose into the blower port on the side of the power head and lock into place Fig 2 5 Choose the desired accessory and insert onto...

Страница 13: ...ough and out of the filter Do not use a filter with holes or tears replace it immediately STORAGE Before storing your vacuum the collection tank should be emptied and cleaned The accessories should be cleaned and stored so they can be readily available when needed Store the wet dry vacuum indoors REPAIRS Repairs for this wet dry vacuum should be performed only by qualified service personnel using ...

Страница 14: ...r the raised lip and tighten down by turning the retainer clockwise do not over tighten Fig 4 5 5 Place the power head back onto the collection tank 1 Unlock and remove the filter retainer by turning the retainer handle counter clockwise Fig 6 2 With the removed power head in an upside down position carefully remove the cartridge filter from the filter cage Fig 7 3 Clean the cartridge filter by ge...

Страница 15: ...idge filter on page 14 3 Carefully slide the foam wet filter down over the filter cage making sure the cage is completely covered Fig 2 3 4 Place the power head onto the collection tank 1 With the removed power head in an upside down position carefully remove the foam wet filter Fig 4 2 Use a mild soap and water solution to wash the foam wet filter and rinse with clean water Fig 5 3 Allow the wet ...

Страница 16: ... dust fireplace soot or ash without a fine dust filter Install the correct cartridge filter Reduced efficiency and motor speed vibration There are blockages in the nozzle hose or the collection tank inlets Unplug and check nozzle hose and collection tank inlets for blockages Cartridge filter is clogged by fine dust Take off the filter and clean it or install a new cartridge filter Filter cleaning ...

Страница 17: ...17 EXPLODED VIEW ...

Страница 18: ...ner 1 6 551416106 Float 1 7 551436113 Filter Cage 1 8 551620103 Latch Assembly 2 9 Collection Tank 1 10 551620105 Vacuum Port Assembly 1 11 551002110 Drain Cap Assembly 1 12 551058106 Caster Foot Assembly 4 13 551620106 EVA Hose 1 14 551109125 Crevice Tool 1 15 551001121 Extension Wand 2 16 551011110 Floor Nozzle 1 17 551011109 Utility Nozzle 1 18 551002118 Foam Filter 1 19 551075110 Dust Bag 1 ...