Using Your Pump Accessory

WARNING: 

To reduce the risk 

of fi re or electric shock, do not 

run vac unattended.

!

Turn on the unit by pushing the switch 

from position “O” to position “l”. The 

symbols used on the switch actuator are 

international “On & Off” symbols. 

“O” is the symbol for “OFF” and “l” is 

the symbol for “ON”.

O = OFF    I = ON     

Your Pump Accessory will work best 

when being used to pump large 

amounts of liquid. If the liquid does not 

fi ll the drum so that it covers the drain 

on the inside of your Wet/Dry Vac, the 

pump may not function properly. Due 

to the function of Wet/Dry Vac and the 

Pump Accessory, the pump will not 

operate properly if your vac is running.

1. Make sure that your pump is 

    connected to the drain of your vac   

    (See Assembly), and that the GFCI is

    functioning properly. If you require   

    a hose, connect it to the outlet of the 

    pump.

2. Close the shut-off valve and vacuum 

    up the intended liquid until your 

    Wet/Dry Vac stops picking up the   

    liquid or until all liquid is cleaned up.

3. Turn your vac off, allowing it to stop     

    completely. Position hose to the 

    desired location to empty drum

5. To verify drum is mostly empty, 

    unplug the pump and vac, remove 

    vacuum powerhead and inspect the 

    drum contents. If liquid is still in 

    drum, see “Troubleshooting” section 

    on page 11.

NOTE: Do not run pump dry or damage 

may occur to internal components of 

the pump and void warranty.

6. Unplug the pump, unplug and 

    remove the powerhead of your 

    Wet/Dry Vac and clear any debris   

    that may have collected on or near   

    the strainer of the pump. Reinstall  

    the power head and repeat steps 2  

    through 5 as required.

    contents. Open the shut-off valve 

    located between the outlet of the  

    Pump Accessory and the garden 

    hose.

4. Turn your pump on allowing it to   

    pump out as much of the liquid in 

    the drum as possible. When you 

    notice that the pump is no longer 

    moving any water through the 

    hose and the speed of the motor     

    increases, turn the pump off.

ON/OFF
Switch

Closed 

Position

Open 

Position

Shut-off Valve

Содержание PE401

Страница 1: ...PE401 FOR YOUR SAFETY Read and understand this manual before use Keep this manual for future reference www vacmaster com Cleva North America 601 Regent Park Court Greenville SC 29607 3084514 Conforms to UL Standard 1017 Certified to CSA STD C22 2 No 243 10 ...

Страница 2: ...roducing a high quality durable product This Vacmaster product carries a limited one 1 year warranty against defects in workmanship and materials from date of purchase under normal household use If product is to be used for commercial industrial or rental use a 90 day limited warranty will apply Warranty does not apply to defects due to direct or indirect abuse negligence misuse accidents repairs ...

Страница 3: ...mping flammable or combustible liquids gases or explosive dusts such as gasoline or other fuels lighter fluid cleaners oil based paints natural gas hydrogen coal dust magnesium dust grain dust or gun powder Keep cord away from heated surfaces Do not expose to rain For indoors use only Do not unplug by pulling on cord To unplug grasp the GFCI Ground Fault Circuit Interrupt plug not the cord Do not ...

Страница 4: ...e the following warnings that appear on the motor housing of your Pump Accessory and GFCI housing WARNING FOR YOUR OWN SAFETY READ AND UNDERSTAND OPERATOR S MANUAL DO NOT RUN UNATTENDED DO NOT PICK UP HOT ASHES COALS TOXIC FLAMMABLE OR OTHER HAZARDOUS MATERIALS DO NOT USE AROUND EXPLOSIVE LIQUIDS OR VAPORS WARNING To reduce the risk of electrocution complete the following steps 1 Plug in receptacl...

Страница 5: ... the adapter must be connected to a permanent ground such as a properly grounded outlet box cover Whenever the adapter is used it must be held in place by a metal screw Please consult a qualified electrician if there is question how to connect to a ground with a 2 prong outlet The pump should not be plugged into this outlet if it is not grounded WARNING Risk of electric shock This pump is supplied...

Страница 6: ...elf with the following product and features and read the entire owner s manual for specific usage of your new Pump Accessory IMPORTANT NOTE Please Read This Manual Carefully Getting to Know Your Pump Pump Accessory Pump Outlet Drain Cap GFCI Plug Pump Inlet Cord Shut off Valve ON OFF Switch Adapter Strainer Familiarize yourself with the control and features of your Pump Accessory before operating ...

Страница 7: ...igned to prohibit rotation of the pump after installation so proper alignment must be achieved before the coupler has been tightened 3 After the pump assembly is securely attached to the drain the shut off valve should be installed to the outlet of the pump and turned to the closed position Without this shut off valve installed liquid will leak through the pump outlet Connect a standard size garde...

Страница 8: ...educe the risk of fire or explosion do not operate this vac in areas with flammable gases vapors or explosive dust in the air Flammable gases or vapors include but are not limited to lighter fluid solvent type cleaners oil base paints gasoline alcohol or aerosol sprays Explosive dusts include but are not limited to coal magnesium aluminum grain or gun powder Do not vacuum explosive dust flammable ...

Страница 9: ...nded liquid until your Wet Dry Vac stops picking up the liquid or until all liquid is cleaned up 3 Turn your vac off allowing it to stop completely Position hose to the desired location to empty drum 5 To verify drum is mostly empty unplug the pump and vac remove vacuum powerhead and inspect the drum contents If liquid is still in drum see Troubleshooting section on page 11 NOTE Do not run pump dr...

Страница 10: ...cloth dampened with warm water and mild soap Remove any excess water or debris with a dry cloth Cord Storage Wrap the cord up and use the attached hook loop strap to retain the cord Storing the Pump Accessory When not in use store your Pump Accessory in a cool dry location with the cord wrapped up using the supplied hook loop cord wrap The original Wet Dry Vac drain cap should then be installed on...

Страница 11: ...let does not exceed 50 feet 1 Check GFCI see page 8 2 Make sure Pump Accessory is plugged in 3 Make sure switch is on 4 Check house circuit breaker fuse 1 Check fit on adapter 2 Check coupler fit and O ring 3 Check shut off valve fit and O ring 4 Check garden hose fit and make sure hose washer is in place 1 Unplug Pump Accessory 2 Check for blockage 3 If Pump Accessory continues to have an electri...

Страница 12: ...1 7 PA01BZ 20 60 Owner s Manual 1 WARNING To reduce the risk of injury from electrical shock unplug power cord before servicing the Wet Dry Vac Pump Accessory 1 2 3 4 5 6 7 REPAIR PARTS PE401 Wet Dry Vac Pump Accessory Always order by part number not by key number Always mention the model number when ordering parts The model number is found on the serial plate located on the pump To order parts ca...

Отзывы: