VACITUP 223100 Скачать руководство пользователя страница 11

 

www.vacitup.se

 

10 

 

Replacement of the dust bag

 

 

1.

 

Turn the central vacuum off and unplug the 
power supply. 

 

2.

 

Pull the lever located to the side of the dust 
container all the way to the right. 
 

3.

 

Swing out the dust container by pulling the 
handle. 

 

4.

 

Close the dust bag with the sealing strip, 
which is found at the upper edge of the 
plastic bag. 
 

5.

 

Lift out the dust bag carefully to keep it from 
being damaged. 

 

6.

 

Fit a new dust bag in the dust container and 
fold the upper edge of the bag around the 
edge of the dust container. 

 

7.

 

Using the handle, push the dust container 
back until it stops. 
 

8.

 

Hold the dust container in this position and 
move the lever at the same time to the left 
until it stops. 

 

 
The dust bag might contain hazardous and poisonous dust and should therefore be disposed of according 
to governmental regulations. Used dust bags should always be closed completely and be treated carefully. 
Use only original dust bags.

 

 

Lever 

Handle 

Lever

 

Handle 

Sealing 
strip 

Содержание 223100

Страница 1: ...Vacitup AB Smedv gen 24 SE 433 61 Stenkullen Sweden Tel 46 0 31 44 32 00 info vacitup se www vacitup se USER S MANUAL CENTRAL VACUUM CLEANER 3 4 and 5 5 kW...

Страница 2: ...rnings 8 Installation 9 Maintenance and Service 10 Replacement of the Dust Bag 11 Replacement of the Filter 12 Manual Cleaning of the Filter Back Flush 13 Trouble Shooting 14 Service Protocol 15 EC De...

Страница 3: ...mage to the machine Read carefully Take the time to read this manual before using the machine for the first time It contains useful information about its installation its functions and its maintenance...

Страница 4: ...formed only by trained and authorised staff All instructions in this manual are to be followed for the warranty to be valid Performing an action against recommended instructions will invalidate the wa...

Страница 5: ...l Vacuum Cleaner Filter cleaning handle Top of the filter housing Electrical cabinet Cyclone filter housing with filter Lenses for level guard optional Lever to open the dust container Dust container...

Страница 6: ...f the central vacuum cleaner It is worth noting that 98 of the machine is recyclable The remaining portion is made of electrical components No solvents are used during the coating neither for cleaning...

Страница 7: ...lixon Clixon Clixon Clixon Clixon Airflow m3 h 330 420 330 420 650 Vacuum mbar 280 280 300 300 280 Inlet mm 63 63 63 63 76 Outlet mm 80 80 80 80 80 Filter size m2 4 0 4 0 4 0 4 0 4 0 Filtration BIA Cl...

Страница 8: ...cumstances be used for the suction of burning glowing explosive or inflammable fluids or materials 5 If the filter shows any sign of damage it must be replaced before the vacuum cleaner is used in ord...

Страница 9: ...quire additional room above the machine 5 The floor must be even and stable enough to carry the weight of the vacuum cleaner 6 The central vacuum cleaner must be anchored to the floor to keep it from...

Страница 10: ...pending on use 4 Change the filter if it shows any sign of damage or has a hole 5 Change the dust bag before it becomes too full 6 Check that the cooling air intake to the vacuum pipe is free 7 Check...

Страница 11: ...it from being damaged 6 Fit a new dust bag in the dust container and fold the upper edge of the bag around the edge of the dust container 7 Using the handle push the dust container back until it stops...

Страница 12: ...e locking ring that hold the top of the filter housing 4 Lift off the top 5 Carefully lift the filter out of the housing so that the dust does not spread out 6 Place the filter upside down on the floo...

Страница 13: ...eaner by turning the main switch to the OFF position 4 Wait until the pump has stopped completely which takes approximately 20 seconds 5 Pull the filter cleaning handle again and then push it all the...

Страница 14: ...The yellow lamp FILTER is lit on applicable models a Take out and clean the filter Check for damage or holes in the filter If it is damaged the filter must be replaced 4 The red lamp LEVEL is lit on...

Страница 15: ...flush function 6 Test and check any discordant sounds from the pump System Rem Missing Done 1 Check vacuum inlets Density and function 2 Check automatic hose hanger Density and function of the valve...

Страница 16: ...cuum Cleaner 3 4 and 5 5 kW We declare that the above mentioned products comply with the following European Directives Low Voltage Directive IEC EN 60335 2 69 IEC EN 60335 1 Machinery Directive EN ISO...

Отзывы: