Technical Brief: 

How Vacuum Pumps Work

 

Operating / Installation Instructions: 

VP01QRBV Solenoid Controlled Venturi Vacuum

 Pump

 

 

Proudly Made In The USA

Opera ng and Installa on Instruc ons:

1. 

Mount pump. Pump has two through holes that accept 4-40 
(M3) screws (screws not supplied). Pump works in any 
orienta on.

2.   

A ach air line to supply port.  A ach vacuum line to vacuum 
port (when not directly a aching vacuum cup).  Use 1/4” 
tubing [6mm] (minimum) for vacuum and air supply ports.

3. 

Confirm proper solenoid voltage located on the side of the 
solenoid valve.

4.   

Connect posi ve and nega ve power supplies (24 VDC or 110 VAC). Check wiring schema c to right to 
ensure proper connec on. Black lead -24 V DC, red lead +24 V DC). Pump is also available with an 
op onal 3-pin male M8 connector.

5. 

Turn on compressed air and regulate to specified pressure (80 PSI standard, -60 models 60 PSI).  Set 
regulator while pump is opera ng.

6. 

Energize vacuum valve to create vacuum.

7. 

De-energize valve to turn off vacuum

8. 

Energize vacuum valve to create vacuum.

9. 

De-energize valve to turn off vacuum

Principles of Opera on

Compressed air is supplied to both normally closed (N.C.) 
solenoid valves simultaneously. To create vacuum, energize the 
first (vacuum) solenoid valve to allow the compressed air to 
flow to the miniature venturi cartridge resul ng in 
instantaneous vacuum.
 
To release the part, de-energize the vacuum solenoid while 
energizing the blow-off solenoid. Because the blow-off air is at 
line pressure, a very powerful blow-off will be created.

Vacuum is produced in a venturi cartridge by forcing 
compressed air through a limi ng orifice (nozzle). As the air 
exits the orifice, it expands, increasing in velocity to supersonic 
speed before entering the venturi sec on (diffuser). This creates 
a vacuum at the inlet port, located between the nozzle and 
diffuser. T e nozzle and diffuser combine to create a vacuum 

h

cartridge. The precise fit of the nozzle to the diffuser is cri cal 
to the pump func oning properly.

Vacuum

Air Supply

Exhaust