background image

Technical Brief: 

Vacuum System Design:

Choosing The Correct Sized Tubing

Technical Brief: 

How Vacuum Pumps Work

Operating Instructions: VP 00-10-20-80-90 Series Modular Vacuum Pumps  – 2

© 2014 Vaccon Company

The recommended tubing sizes are based on polyethylene or polyurethane tubing with 0.062” [ / ”, 1.5 mm] wall thickness
Note: Vaccon discourages the use of quick disconnect fi ngs on all connec ons

VP00

VP20/80/90

VP10

End Views:

Air Supply

Ports

  

Top Views:

Vacuum

Ports

Operating / Installation Instructions: 

 

VP 00-10-20-80-90

Modular Venturi Vacuum Pump Series

Addi onal Informa on

VP Series

Model

Air Supply Port

Threads

Recommended 

Air Supply Line

(outer diameter)

Vacuum Port 

Threads

Recommended 

Vacuum Line

(outer diameter)

VP00-60 (M,H) Series

10-32 UNC Female

¼" 

[6 mm]

10-32 UNC Female

¼" 

[6 mm]

VP10-(60,90) (L,M,H) Series

¼ 

NPT

¼" 

[6 mm]

⅛ 

NPT

¼" 

[6 mm]

VP10-(100,150) (L,M,H) Series

¼ 

NPT

⅜" 

[10 mm]

⅛ 

NPT

⅜" 

[10 mm]

VP20-(60,90) (L,M,H) Series

¼ 

NPT

¼" 

[6 mm]

¼ 

NPT

¼" 

[6 mm]

VP20-(100,150) (L,M,H) Series

¼ 

NPT

⅜" 

[10 mm]

¼ 

NPT

⅜" 

[10 mm]

VP80-200 (L,M,H) Series

¼ 

NPT

⅜"

 [10 mm]

⅜ 

NPT

⅜"

 [10 mm]

VP80-250 (L,M,H) Series

¼ 

NPT

⅜" 

[10 mm]

⅜ 

NPT

½"

 [12 mm]

VP90-300 (L,M,H) Series

⅜ 

NPT

½" 

[12 mm]

½ 

NPT

½" 

[12 mm]

VP90-350 (L,M,H) Series

 NPT

½"

 [12 mm]

½ 

NPT

½" [

12 mm]

Отзывы: