Operation after power failure
-----------------------------------
The device has the memory function for the set value. When the power is
restored after the power failure, the device will continue the operation before
the power failure.
Warning
O
nce the power of the refrigerator is cut off, it will take
more than five minutes to turn it on again to avoid damages
to the compressor or system.
W
hen the refrigerator is not used for a long time, unplug
the power plug and turn off the battery switch (applicable
to battery items) to prevent electric shock, leakage or fire
caused by aging of the power cord.
I f the refrigerator is left idle for a long time in an
unsupervised area, please ensure that children do
not approach the refrigerator and the door cannot be
completely closed.
Initial start-up
------------------------------------------------------
13
Please observe the following rules when conducting initial start-up:
1.Under no-load condition, please connect the power plug to right plugboard,
and the plugboard should not be shared with other appliances.
2.After turning on the power supply, turn on the battery switch of the device,
check if the inner LED light works properly.
3
.Set parameter of cabinet temperature, high(low) temperature alarm deviation,
etc according to actual need. Default setting temperature is 5°C, high
temperature alarm is 8°C and the low temperature alarm is 2°C, please refer
to the operation instructions below for details.
4
.“H1” alarm occurs at the initial operation stage, indicates the temperature
in cabinet is high. The alarm will stop when the temperature in cabinet drops to
the set temperature.
5
.Observe equipment operation for more than 3 hours, ensure equipment
runs stably, store items in cabinet in batches.