10
Slave model
Once the type of our installation has been chosen, we can select the data source from which
Trydan will obtain the consumption data and, if necessary, photovoltaic generation.
The currently supported models are:
- V2C_1.0 (Previous slave not compatible with photovoltaic)
- V2C_2.0 ((New slave with three-phase integration and PV on three-phase)
- Huawei SUN2000 Inverters
- Solax Inverters
- Kostal Inverters
- Fronius Inverters
- Shelly (single-phase or three-phase)
A specific manual is available for the installation and integration of each one of the
inverters.
Contracted power
After selecting our slave, we must indicate the contracted power. This power will be the
maximum limit of the total consumption that Trydan will use to adjust the load current. This
limit can be modified and programmed by hours through the V2C Cloud APP, so if this
parameter is modified from this menu, this programming will be DELETED.
Maximum intensity
Once the programmed power has been configured, we can select the maximum intensity at
which we want the dynamic control to act. If the consumption of the home allows it, this
intensity will be the maximum intensity at which Trydan will charge your vehicle (Limit 7 - 32A).
Minimum intensity
Once the maximum current has been set, we can now select the minimum current we want the
dynamic control to operate at. If the consumption is too high to maintain this minimum current,
Trydan will stop charging until the total consumption is low enough to charge our car at this
current. It is therefore advisable not to set this parameter too high (Lim. 6 - 32A).
You can consult the different photovoltaic operating modes at the following link:
https://v2charge.com/photovoltaic-modes-of-operation/