RADIO CHANNEL CONFIGURATION 

When the network is not configured, the base unit monitors the 16 possible radio channels and registers activity present in the
environment; for establishment of a new network, it is appropriate to select a channel on which there is low radio activity, in order to
avoid interference.

Set dip-switch 8 to ON: the green and red LEDs indicate the quality of the channel selected:
-

red LED:

unusable channel

-

green LED:

single flash - medium quality
double flash – good quality
triple flash – best channel

Alter dip-switches 3 to 6 in order to change the radio channel until the best channel is identified.

PLEASE NOTE:  Once the channel is selected, return dip-switch 8 to OFF

PLEASE NOTE:  The channel cannot be modified after the network has been configured.

If dip-switches 3 to 6 are altered with the network configured, the red LED will emit a series of flashes in fours.

RESET BASE UNIT CONFIGURATION

To delete the configuration of a base, it is necessary to press and hold the PROG button on the base unit until the red LED starts to flash.
Then release the button and repeat the radio channel configuration.

ASSOCIATING THE SENSOR WITH THE BASE

During association, the sensor communicates the installed configuration to the base.

NOTE: if a sensor is not connected to any edge, it cannot be associated with a base.

CAUTION: make sure edges are connected properly to the sensors prior to proceeding.
When association is complete, it is no longer possible to alter the sensor connections.

Install the sensors by following the instructions attached to the product, then proceed as follows:

To associate an edge with 

unit 1

, proceed as follows:

1.

Press the PROG button on the base unit once: the ALARM LED emits single flashes

2.

Press and hold the sensor SET button until LED L3 flashes intensely and regularly, then release the button. 

3.

The base automatically exits acquisition mode and the sensor starts to transmit with a period of 15 seconds

To associate an edge with 

unit 2

, proceed as follows:

1.

Press the PROG button on the base unit twice: the ALARM LED emits dual flashes

2.

Press and hold the sensor SET button until LED L3 flashes intensely and regularly, then release the button. 

3.

The base automatically exits acquisition mode and the sensor starts to transmit with a period of 15 seconds

To associate an edge with 

both units

, proceed as follows:

1.

Press the PROG button on the base unit 3 times: the ALARM LED emits triple flashes

2.

Press and hold the sensor SET button until LED L3 flashes intensely and regularly, then release the button. 

3.

The base automatically exits acquisition mode and the sensor starts to transmit with a period of 15 seconds

PLEASE NOTE:

Association must be completed within 15 seconds, otherwise the base unit exits acquisition mode.

4.

On completion, close the sensor casing and tighten the screws once more.

5.

Repeat the operation for the other sensors in the network. When all the sensors have been installed and associated, 
close the base unit casing.

EDGE TESTING

Activate the base unit testing method by setting dip-switch 8 to ON. Press the edge to verify that:

1.

the LED on the sensor remains fixed and on

2.

the red (OUT1/OUT2) LED on the base unit comes on

3.

The control unit recognises the alarm on the input where the output from the u

PLEASE NOTE: Remember to return dip-switch 8 to OFF on completion of the test.

Содержание WES-BASE

Страница 1: ...IL CONTROLLO VIA RADIO DELLE COSTE DI SICUREZZA RADIO CONTROL SYSTEM FOR SAFETY EDGES SYST ME POUR LE CONTR LE PAR RADIO DES BARRES PALPEUSES DE S CURIT SISTEMA PARA EL CONTROL V A RADIO DE LAS BANDAS...

Страница 2: ......

Страница 3: ...armonisation of legislation from member states regarding machinery and that the technical standards indicated below have been applied EN 301 489 3 2002 Electromagnetic compatibility and questions rela...

Страница 4: ...d with UNIT 1 and UNIT 2 respectively The BAT LOW output breaker NC opens when a sensor indicates the low battery status PLEASE NOTE UNIT 1 and UNIT 2 are used to manage 2 edge units in different mode...

Страница 5: ...n safety input OUT1 Unit 1 edge input OUT2 Unit 2 edge input BAT LOW Can be used to indicate low battery level START Photocell TX supply BASE UNIT ELECTRICAL CONNECTIONS DIP SWITCHES The device has 8...

Страница 6: ...hen proceed as follows To associate an edge with unit 1 proceed as follows 1 Press the PROG button on the base unit once the ALARM LED emits single flashes 2 Press and hold the sensor SET button until...

Страница 7: ...lashes depending on the unit being configured button pressed once twice or three times Slow flashing during network deletion button pressed and held down Off Off Off CONDITION GREEN LED RADIO RED LED...

Страница 8: ...OW LEDs off The system is operating normally If the control unit does not show that the edge input has been closed there is a connection problem broken wire 4 Observe the LED for a sensor Is the LED o...

Отзывы: