V2 RIF50 Скачать руководство пользователя страница 4

E

N

G

LI

SH

The devices in the series RIF50 - DFN are a security systems for
controland observation of passages, automatic gates and doors. It
can be used also for pedestrian and car crossing.
It is composed by a transmitter and a receiver housed in special
waterproof boxes, that permite the installation in the external or
internal part of a building.
The system doesn't need a centring adjustment; the receiver LED
displays the perfect alignment of the photocells, therefore it
allows an easy and fast installation.

INSTALLATION (Fig. 1)

For the system to function correctly, it is essential that the flatness
and linearity of the surfaces intended for installation be checked,
then FIX THE PROJECTOR ALONG THE SAME GEOMETRICAL AXIS
AND AT THE SAME HEIGHT ABOVE THE GROUND, IN FRONT OF
THE RECEIVER.

For correct installation, follow the instructions below very
carefully:
• Decide where the photocells are to be installed, taking into 

account the need for the photocells to be fixed on a flat, 
linear surface.

m

PLEASE NOTE: position the photocells so as to avoid 

the receiver RX facing into the sun.

• Decide where to place the channels for the power supply 

cables.

• Open the photocell casing and use the base 

A

to mark out 

the positions of the fixing holes.

• Fix the base 

A

and connect-up the terminals.

ELECTRICAL CONNECTIONS

The new range of devices is equipped with a synchronism circuit
allowing the installation of two pairs, even very close together,
without them interfering with one another.

m

PLEASE NOTE: It is essential that the TX and RX 

power supplies be in phase (e.g. TX earth with RX earth
and 24 V AC TX with 24 V AC RX). 

Synchronised operation: 

supply both pairs of photocells with

AC current, inverting the polarity between the first and second
pairs (fig. 2).

Non-synchronised operation: 

supply both pairs of photocells

with DC current, and install both pairs inversely with respect to
one another (fig. 3).

ADJUSTMENT

Having completed the installation, check that the system is
operating correctly:

1.

Ensure there are no obstacles between the transmitter and 
the receiver.

2.

Power-up the system: 
- The receiver LED is off: The photocell is not centred; 

perform centring.

- The receiver LED is on: the photocell is centred.

m

WARNING: If the receiver LED flashes, the power 

supply of TX and RX is out of phase.
Check the electrical connections.

3.

Apply the adhesive gasket 

D

inside the cover. As regards DFN: 

if there is not a strong solar exposure, please put the gasket 
with the small opening positioned on the lens of TX and RX. 
Otherwise please put the gasket with the small opening 
positioned on RX lens (the range is so reduced to 13 meters).

m

PLEASE NOTE:  incorrect insertion of the gasket 

seriously compromises the watertight seal of the casing.

5.

Place the cover 

B

over the photocell and ensure it is operating 

correctly without removing the adhesive attenuation filter 

C

(the filter simulates adverse weather conditions such as rain, 
fog etc.)

6.

Then remove the attenuation filter.

7.

Break the infrared beam a number of times: the receiver LED 
must switch itself off and the relay must switch.

The manufacturer cannot be held reponsible for any
damage caused by iproper, erroneus or unreasonable use

TECHNICAL SPECIFICATIONS

DECLARATION OF CONFORMITY

V2 S.p.A. hereby declare that RIF50 - DFN equipment conforms
to the essential requirements established in the electromagnetic
compatibility directive 

89/336/CEE

Racconigi, 10

th 

September 2009

Legal representative, V2 S.p.A.

Cosimo De Falco

RIF50

DFN

Dimensions

89x55x24 mm

76x66x30 mm

Optical range

25 m

Power supply

12÷24 Vac/dc

Signal

modulated infrared 833 Hz

l

= 950 nm

Relay contact

1A max 30 Vdc

Absorption

TX 20 mA RX 25 mA

Operating temperature

-20°C / +60°C

Отзывы: