4. SENSOR THRESHOLD LEVELS

To display and modify the threshold levels of the various sensors,
follow this procedure:

a) WIND Sensor

m

CAUTION:

To cause the sunshade to close, the wind sensor 

must detect a value greater than the set threshold for at least 5
seconds. Closure of the sunshade due to strong wind causes the
system to block for 8 minutes.

1.

Press 

P2

: the 

WIND

LED will turn on, identifying the wind 

sensor, and at the same time the LED that displays the sensor 
threshold level turns on:
LED 1 = level 1 = 10 km/h (default value)
LED 2 = level 2 = 15 km/h
LED 3 = level 3 = 20 km/h 
LED 4 = level 4 = 30 km/h
LED 5 = level 5 = 40 km/h

2.

To change the set level, press 

P1

a number of times until the 

level you want is displayed (once level 5 is reached, the next 
time it is pressed it restarts from level 1).

b) SUN Sensor

m

CAUTION: 

To cause the sunshade to open, the sun sensor 

must detect a value greater than the set threshold for at least 8
minutes. 
To cause the sunshade to close, the sun sensor must detect a
value less than the set threshold for at least 8 minutes.

1.

Press 

P2

twice: the 

SUN

LED will turn on, identifying the sun 

sensor, and at the same time the LED that displays the sensor 
threshold level turns on:
LEDs OFF = sensor disabled
LED 1 = level 1 = 2 klux
LED 2 = level 2 = 5 klux 
LED 3 = level 3 = 10 klux (default value)
LED 4 = level 4 = 20 klux
LED 5 = level 5 = 40 klux

2.

To change the set level, press 

P1

a number of times until the 

level you want is displayed (once level 5 is reached, the next 
time it is pressed it restarts from level 1).

c) TEMPERATURE Sensor

This function allows the temperature level below which the
device must not open the sunshade, even if the light intensity is
greater than the threshold level set.

This function is very useful in countries with cold climates, where
it is often sunny but very cold. Under these conditions it is not
necessary that the sunshade open, which would prohibit the
sun's rays from heating the inside space.

1.

Press 

P2

three times: the 

TEMP

LED will turn on, identifying

the temperature sensor, and at the same time the LED that
displays the sensor threshold level turns on:

LEDs OFF = sensor disabled
LED 1=Level 1 = sensor disabled (default value)
LED 2 = Level 2 = 0 °C
LED 3 = Level 3 = 5 °C
LED 4 = Level 4 = 10 °C 
LED 5 = Level 5 = 15 °C

2.

To change the set level, press 

P1

a number of times until the

level you want is displayed (once level 5 is reached, the next time
it is pressed it restar

DECLARATION OF CONFORMITY

V2 SPA herewith states that the HURRICANE-RS models
are in accordance with the following EEC directive:

2004/108/CEE

EMC directive

2006/95/CEE

Electrical safety directive

99/05/CEE 

Radio directive

Racconigi, 02/02/2010
V2 SPA legal representative 

Cosimo De Falco