ENGLISH

- 10 -

LOCK

1 2 3 4 5 6 7 8 9 10 11 12

RECEIVER

L1 L2

A1

POWER

WORK

PAUSE

DELAY

A2

L3 L4 L5 L6 L7 L8 L9 L10 L11

K1 K2 K3 K4 K5 K6 K7 K8 K9 K10 N mains L

ANT

ST

AR

T

START

STOP

EDGE

overload

mains

START P.

PHOTO

STOP

ST

AR

T P

.

PHOTO

(Photo / Edge T

est)

EDGE

COM

24V

AC - 3W

GND

OPEN

COM

CLOSE

OPEN

LAMP

Max 40W

NEUTRAL

PHASE

COM

CLOSE

24V

AC

COUR

TESY LIGHT

CONT

ACT

M1

M2

ELECTRICAL CONNECTION 

A1

Antenna

A2

Antenna shield

L1

Opening command for a standard connection device 
with switch normally open.

L2

Pedestrian opening command for a standard 
connection device with switch normally open.

L3

STOP command. N.C. switch

L4

Photocell. N.C. switch

L5

Edge. Switch N.C. or resistive rubber edge

L6

Commands common (-) line

L7 - L8

24 VAC power output for photocells and other 
accessories

L8 - L9

Power supply for functional test TX photocell 

L10 - L11

12V electric lock

K1 - K2

Courtesy light timer activation switch

K3

Motor 1 open

K4

Motor 1 common

K5

Motor 1 close

K6

Motor 2 open

K7

Motor 2 common

K8

Motor 2 closed

K9 - K10

230V - 40W / 120V - 40W blinker

N

230V / 120V power supply - neutral

L

230V / 120V power supply - phase

m

 

PLEASE NOTE:  If not used, the normally closed 

inputs (STOP, PHOTO, EDGE) must be jumpered with the 
commands common line COM (-) 

Содержание CITY11

Страница 1: ...not come into contact with safety low voltage ones The plastic case has an IP55 insulation to connect flexible or rigid pipes use pipefittings having the same insulation level Installation requires m...

Страница 2: ...an be used with two settings 1 Photocell always active Intervention of the photocell during opening or closing causes the gate to stop When the photocell restores the gate re opens completely 2 Photoc...

Страница 3: ...closed In both modes it is possible to disable the Start command during gate opening by means of dip switch 3 Connect the start input control device cables between terminals L1 and L6 on the control...

Страница 4: ...an opening command for a standard connection device with switch normally open L3 STOP command N C switch L4 Photocell N C switch L5 Edge Switch N C or resistive rubber edge L6 Commands common line L7...

Страница 5: ...h the slow down function disabled DIP 5 OFF mWARNING the adjustment of times has to be made when the gate is still POWER MIN MAX WORK 50 18 2 2 45 PAUSE 150 30 2 2 90 DELAY 90 15 0 0 45 POWER motor po...

Страница 6: ...upplemental time in order to compensate for the inertia of the gate 8 Photocell ON Always active Intervention of the photocell during opening or closing causes the gate to stop When the photocell rest...

Страница 7: ...cas de d tachement d un conducteur on vite que les partie en tension puissent aller en contact avec les parties faible tension de s curit Pour la connexion de tubes rigides ou flexibles utiliser des...

Отзывы: