ENGLISH
- 51 -
PARAMETER
VALUE
DESCRIPTION
DEFAULT
MEMO
FrEn
Brake Function
5
1 - 1 0
When a sliding motor is used with a very heavy gate, because of the
inertia, the gate does not block immediately when stopped and its motion
can last for another 10 cm, compromising the working of the safety
devices.
This menu allows enabling the brake function thanks to which it is
possible to block immediately the gate after a control or the intervention
of a safety device.
The brake power is proportional to the set value
WARNING: each braking entails a mechanical stress to the
components of the motor. We suggest to set the minimum value
with which there is a satisfactory stop distance.
0
Function deactivated
rA.AP
Slow down in opening
15
0 - 1 00
This menu allows regulating the percentage of the ride/drive that is carried
out at reduced speed during the last opening stretch
rA.Ch
Slow down in closing
15
0 - 1 00
This menu allows regulating the percentage of the ride/drive that is carried
out at reduced speed during the last closing stretch
St .AP
Start command during the opening phase
This menu allows fixing the control unit conduct in case it receives a Start
command during the opening phase
PAUS
PAUS
The gate stops and goes to pause
ChiU
The gate immediately starts closing
no
The gate go on with the opening phase (command is ignored)
St .Ch
Start command during the closing phase
This menu allows fixing the control unit conduct in case it receives a Start
command during the closing phase
StoP
StoP
The gate stops and its cycle is considered as finished
APEr
The gate opens again
St .PA
Start command during the pause
This menu allows fixing the control unit conduct in case it receives a Start
command when the gate is open during its pause phase
ChiU
ChiU
The gate starts closing
no
Command is ignored
PAUS
The pause time is reset (
Ch.AU
)
SP.AP
Pedestrian Start during the partial opening phase
This menu allows fixing the control unit conduct in case it receives a
Pedestrian Start command during the partial opening phase.
WARNING: a Start command in any phase of partial opening will
cause the total opening; the Start Pedestrian command is always
ignored during a total opening
PAUS
PAUS
The gate stops and goes to pause
ChiU
The gate immediately starts closing
no
The gate goes on with the opening phase (command is ignored)
Содержание AYROS
Страница 30: ...ITALIANO 28 ...
Страница 32: ...ITALIANO 30 ...
Страница 60: ...ENGLISH 58 ...
Страница 62: ...ENGLISH 60 ...
Страница 90: ...FRANÇAIS 88 ...
Страница 92: ...FRANÇAIS 90 ...
Страница 120: ...ESPAÑOL 118 ...
Страница 122: ...ESPAÑOL 120 ...
Страница 150: ... 148 PORTUGUÊS ...
Страница 152: ... 150 PORTUGUÊS ...
Страница 180: ...DEUTSCH 178 ...
Страница 182: ...DEUTSCH 180 ...
Страница 210: ...NEDERLANDS 208 ...
Страница 212: ...NEDERLANDS 210 ...
Страница 240: ... 238 POLSKI ...
Страница 242: ...POLSKI ...
Страница 243: ......