Installation instructions
Induction hob
GK46TIG | GK46TIM | GK47TIMAS
1021071-R01
28/11/2016
3
Electrical connection
Electrical connections must be carried out by qualified personnel in accordance with the guidelines and standards
for low-voltage installations and the specifications of the local electricity supply companies.
A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications.
An all-pole mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches,
plug and socket devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-
poles switching are permissible as isolating devices. Effective earthing and separately installed neutral and earth con-
ductors ensure safe and fault-free operation. After installation, live parts and cables with basic insulation must not be ac-
cessible. Check old installations.
▸
The appliance is designed for use up to a max. altitude of 2000 m above sea level.
▸
Refer to the identification plate for information on the required mains voltage, current type and fuse protection.
The appliance is equipped with a connection cable which must be connected to an on-site junction box.
Installation pipe
Distribution box
Clamp
brown + black
blue
yellow/green
black
blue
yellow/green
brown
L2
L1
N
N
L1
PE/
PE/
400 V 2N~
230 V~
Error message U400
Faulty connection:
A pole conductor has been connected to the connection terminal for neutral conductors.
Quickly disconnect the appliance from the mains!
Ventilation
In order to guarantee good ventilation, a space of ≥ 10 mm
height is necessary beneath the appliance.
1.
The rear panel of the base unit must be open around the
work surface cut-out to guarantee continuous air circula-
tion via the ventilation slits.
The air must be drawn in from outside the cabinet and
be able to circulate freely from inside the cabinet to the
hob.
2.
Alternatively, a concealed fresh air supply can ensure air
circulation inside the cabinet.
In order that enough cold air can be drawn in, there
must be a continuous circulation of fresh air that extends
outside the cabinet.
The air must be drawn in from outside the cabinet and
be able to circulate freely from inside the cabinet to the
hob.
≥15
2
1