Installation guidelines

The appliance is designed for niches with a width of 600 mm (EURO) and a height of 820–870 mm.

A

Insert the plug into the mains socket.

A

Door opening angle 105°/90° (with enclosed pin)

The values for the door panels are recommendations only and may deviate depending on kitchen cabinet manufacturer.

B

For plinth height 100–150 mm (niche height 820–870 mm), leave the plinth strip and ventilation grille. 

C

For plinth height 135-185 mm (niche height 820–870 mm), clip out and shorten the ventilation grille.
For plinth height >135 mm (niche height 820 mm), make cut-out in plinth at height of 135 mm.
For plinth height >185 mm (niche height 870 mm), make cut-out in plinth at height of 185 mm.
A plinth recess of 30–60 mm is achieved by pushing back the ventilation grille. For a plinth recess 60–78 mm, put the plinth
panel behind the ventilation grille.

 

Appliance 597

Niche 600

Shorten

B

  100…150

C

  135…185

190

30

Niche 820–870 (max. 890)

0–50 adjustable (max. 70)

Ventilation grille
integrated in plinth

Identificaton plate is
located on left, next-
to salad crisper

Appliance 545

Niche 550

17

220

B

30…60

660

min. 20

Appliance 819–869 (max. 889)

a

287

287

289.5

289.5

A

Door panel 595

b

419.3

57

min. 680

a

  Recommended gap:.3 mm

b

  Recommended:

        70.5 mm

73.5 – 

a

 = 

b

 

73.5 – 3 = 70.5

Measurements for plinth height 150 mm

Niche

820…870

}