V-ZUG GS60SZGVI Скачать руководство пользователя страница 3

J163113-R06

Dishwasher

EN – 

Installation instructions

1.

Water inlet

Working pressure

Inlet pipe, Aqua-Stop

Water outlet pipe

Disconnect feeder

Water/electrical connection

<60 °C

1–10 bar

1,5 m

G¾"

1,6 m

ø 22 mm

0,1–1 MPa

Minimum ambient temperature

+5 °C

2.

Remove all flaps from drain trap

Dummy and non-return valve

3.

Clean drain trap 

E.g. with flexible brush

If the water pressure is too high, a pressure reducer valve must be fitted.

Содержание GS60SZGVI

Страница 1: ...0 80 mm 80 40 Appliance components Front panel decorative system Base Recess for pipes Water tap Power socket Drain trap connection Mains connection Drain pipe Aqua Stop inlet pipe Before installation please read the safety precautions on the reverse side ...

Страница 2: ...s A plug in appliance may only be connected to a socket outlet with earthing contact installed according to specifications An all pole mains isolating device with 3 mm contact opening should be provided in the house wiring system Switches plug and socket devices circuit breakers and fusible cut outs which are accessible after installation and which have all poles switching are permissible as isola...

Страница 3: ...utlet pipe Disconnect feeder Water electrical connection 60 C 1 10 bar 1 5 m G 1 6 m ø 22 mm 0 1 1 MPa Minimum ambient temperature 5 C 2 Remove all flaps from drain trap Dummy and non return valve 3 Clean drain trap E g with flexible brush If the water pressure is too high a pressure reducer valve must be fitted ...

Страница 4: ...in hose with clamp 5 Fix drain hose at the top with assembly set 7 6 max 10 Nm Check the connection for leaks Do not bend inlet hose Connect Aqua Stop onto the tap For water pressure at 1 bar Unscrew Aqua Stop and remove flow regulator Replace the filter and seal Set to low water pressure according to service documents ...

Страница 5: ... 1 5 mm 230 V 50 Hz 10 A 3 1 mm 400 V 2N 50 Hz 10 A 4 1 mm Installation test Connect up to building supply Plug in Check connection values The building connection must match the information on the identification plate Connection values Connect feeder again black brown blue yellow green ...

Страница 6: ...ogramme is displayed see operating instructions Water outlet fault Water inlet fault Voltage fault Close appliance door The test starts in 15 seconds within 15 seconds שניות 15 בתוך It takes approx 2 minutes If error messages occur rectify fault according to the operating instructions Installation test Select the test by pressing and holding down the buttons at the same time ...

Отзывы: