Electrical connection
Check that the voltage and power of
the appliance are compatible with
the electrical installation.
The hobs are supplied with a power
cable with a wall socket plug.
Provide an omnipolar cut-off switch
with a minimum contact separation
of 3 mm (except for plug
connections, if the user has access
to it).
Appliances with plugs must only be
connected to sockets that have
earth wires correctly installed.
This appliance is type “Y”: the
supply cable can only be changed
by the Technical Assistance Service
and not by the user. The cable type
and minimum cross-section
(3 x 0.75 mm²) must be respected.
BURNER AND GAS TAP SPECIFICATIONS
The burner must be used with the gas indicated in the table
GAS TYPE
G-110
TOWN GAS
Gas pressure for use
mbar
10
Inner burner tip marking
S
Outer burner tip marking
350
Distance „Z“ outer bushing
mm
7
Nominal
5.40
Consumption (H
s
)
Reduced
kW
≤
0.20
Flow 15°C, 1013 mbar
m³/h
1.231
inner burner
65
Double-flame burner
gas tap by-pass screw marking
outer burner
96 or blank
© V-ZUG Ltd, CH-6301 Zug 2010
V-ZUG Ltd
Industriestrasse 66, CH-6301 Zug
[email protected]; www.vzug.com
J851.113-0 / 1029693