background image

Installation instructions

Built-in control panel
ER2/ER4
Type of construction 55-127

1048746-R01

29/01/2018

1048746-R01

2

Installation

Identification plate

Connection plate

72.5

72.5

Intermediate base only 
removable with tools 

60

≥30

127

3

*

560

20

≥60

≥400

205

600

20

550

S2

37

H

S1

A

B

470

ø7

405

547

124

G

D

E

F

C

* Ventilation slit is not absolutely necessary.

1.

Install hob into worktop in accordance with installation instructions.

2.

Drill 2 holes 

L

 (ø 7 mm) into the base of the cabinet or traverse.

3.

Insert screws 

S1

 with washers 

A

 into holes 

L

 from below and loosely screw both clamping plates 

B

.

4.

Open connection box 

C

.

5.

Connect mains connection cable 

D

 in accordance with connection plate.

– Cable length: With cable inserted, it must be possible to pull switch box about 40 cm out of cut-out.

6.

Fix earth connection 

E

 and use clamp 

F

 to secure the strain relief.

7.

Insert coupling plug 

G

 from hob into switch box. Observing the colour code!

8.

Push built-in wide switch box into cut-out and align. Place angle 

H

 under the clamping plates 

B

. Adjust height using screws 

S2

.

9.

Tighten screws 

S1

.

Отзывы: