CombiSteamer with fixed water connection
Bauform 60-450

1063723-03

11/02/2021

1063723-03

6

Installation test and using for the first time

1.

Remove accessory parts from out of the cooking space.

2.

Remove the sealing film over the water outlet in the cooking space.

3.

Insert the filter over the water outlet in the cooking space.

4.

Carry out initial set-up in accordance with the appliance instructions.

If the message «Check water inlet» appears:

Check that the water inlet is open and water is available.

If the water inlet is open, press the adjusting knob to confirm.

Check that the reinforced hose is free of kinks.

If water still remains in the cooking space, the pumping-off process is repeated more than three times at short
intervals and the «Check water outlet» message appears:

Check that the drain hose is free of kinks.

Lay the drain hose so that the hose content does not run back into the appliance.

1.

2.

3.

Sealing film

Draining the water system prior to maintenance work or transport

Automatic draining of the water system drains the water system by around 90%.

The main parts of the water system cannot be drained without a power supply.

Special care is needed if the descaling was aborted and descaler still remains in the water system.

Close the stopcock.

Briefly disconnect the appliance from the mains. Then switch the power supply back on.

Wait until the pump stops pumping.

Empty the water tank, unhook the reinforced hose.

Disassembly and transport

When pulling out the appliance, continuously feed the hoses from behind.

Avoid contamination from waste water in the reinforced hose.

The appliance must never be tilted more than 45°.