11 Technical data
11
Technical data
External dimensions
▸ See installation instructions
1
Electrical connection
▸ See identification plate
1
11.1
Note for testing institutes
Placing thermocouples between the appliance door and the seal can cause lack of leak-
tightness and thus measuring errors.
The usable volume within the meaning of EN 50304 / EN 60350 is obtained with the
shelf guides disassembled.
General note
Maximum load capacity: 3 kg
11.2
Temperature measurement
The temperature inside the cooking space is measured when the cooking space is
empty according to an internationally accepted standard. Own measurements can be im-
precise and are not suitable for checking the accuracy of the temperature.
11.3
Product fiche
In accordance with EU Regulation No.: 66/2014
Brand
–
V-ZUG Ltd
Type of appliance
–
Steam cookers
Model designation
–
CS4T
Mass of the appliance
kg
35
Number of cavities
–
1
Heat source per cavity
–
Electricity
Volume per cavity
l
48
Energy consumption in conventional mode
1
)
kWh/cycle
–
Energy consumption in hot air / forced convection
mode
2
)
kWh/cycle
0.46
Energy Efficiency Index per cavity
3
)
–
61.2
Measurement and calculation methods used
–
SN EN
60350-1:2016
1
)
Required to heat a standardized load per cavity
2
)
Required to heat a standardized load per cavity
3
)
Measurement methods: see EU Regulation No. 66/2014, Annex II, Chpt. 1
60