3 Operating the appliance

3.2 

Intensive level

The intensive level can be selected in stand-by mode.
▸ Press the 

 button to switch the intensive level on for five minutes.

The 

 button and the button for the power level that was running when the intens-

ive level was started illuminate.

If another power level had been running beforehand, then the appliance will automat-
ically revert to this power level after the five minutes has elapsed.

If the intensive level was selected when in the stand-by mode, the appliance will
switch off after the five minutes.

▸ Press the 

/ /  or   button to stop the intensive level before the five minutes has

elapsed.

3.3 

Illumination

▸ Press the 

 button to switch the illumination on.

▸ Press the 

 button again to switch the illumination off.

3.4 

Saturation indicators

Saturation indicator for the metal grease filters

The   button flashes after 40 operating hours. The saturation level has been reached and
the grease filters must be cleaned.

Saturation indicator for the activated charcoal filters

The saturation level is reached when the   button flashes or within four months at the
latest. Depending on use: Replace the standard activated charcoal filters or clean and re-
place long-life activated charcoal filters.

Resetting the filter saturation indicator

▸ In the stand-by mode, hold the 

 button depressed until an acoustic signal is emitted.

The flashing LEDs   (grease filters) or   (activated charcoal filters) no longer flash.

3.5 

Stand-by

Deactivating the stand-by mode

▸ Hold the 

 button depressed for three seconds.

The appliance is switched off and the LED 

 goes out.

This function is useful when cleaning the hood. The illumination can also be used
when the stand-by mode is activated.

Activating the stand-by mode

▸ Hold the 

 button depressed for three seconds.

The stand-by mode is activated and the LED 

 illuminates.

9

Содержание AiroClearWall V2000 V90

Страница 1: ...Operating instructions AiroClearWall V2000 V90 Range hood...

Страница 2: ...afety precautions Modifications Text diagrams and data correspond to the technical standard of the appliance at the time these operating instructions went to press The right to make technical modifica...

Страница 3: ...lements 8 3 Operating the appliance 8 3 1 Operation 8 3 2 Intensive level 9 3 3 Illumination 9 3 4 Saturation indicators 9 3 5 Stand by 9 4 Care and maintenance 10 4 1 Cleaning the housing 10 4 2 Meta...

Страница 4: ...iance and have understood the haz ards involved Children shall not play with the appliance Cleaning and user mainten ance shall not be undertaken by children without supervi sion If an appliance is no...

Страница 5: ...uctions may cause a fire hazard Do not flamb food under neath the range hood 1 4 Instructions for use Before using for the first time The appliance must be installed and connected to the electricity s...

Страница 6: ...means When cleaning the appliance make sure no water gets inside it Use a mod erately damp cloth only Do not spray the inside or outside of the appliance with water Do not use a steam cleaner If water...

Страница 7: ...cooking area are passed through an activated charcoal filter The filtered air is then circulated back into the room through the side openings If activated charcoal filters are not supplied with the a...

Страница 8: ...ee seconds The stand by mode is activated The button illuminates Pressing the or button switches the appliance on at power level 1 2 3 or in tensive The corresponding button illuminates to indicate wh...

Страница 9: ...etal grease filters The button flashes after 40 operating hours The saturation level has been reached and the grease filters must be cleaned Saturation indicator for the activated charcoal filters The...

Страница 10: ...inside next to the grease filters Clean using a slightly damp cloth and detergent if necessary and wipe dry 4 2 Metal grease filter The filters can be cleaned Removing Swing the glass panel 1 up Press...

Страница 11: ...er display Activating the activated charcoal filter display Only activate this function with the recirculation model To deactivate the stand by mode Hold the button depressed for three seconds Then de...

Страница 12: ...e filter 3 forwards and lift it out of the bracket 4 1 2 3 4 Remove the activated charcoal filter 7 7 Replacing The standard activated filters cannot be washed or regenerated and are replaced As soon...

Страница 13: ...f the long life activated charcoal filter is up to three years Disconnect the power supply and switch off the fuse or circuit breaker Cleaning and regenerating Take the activated charcoal filter mat o...

Страница 14: ...ough air Possible cause Solution Metal grease filters are dirty Clean metal grease filters Only for recirculation model The activ ated charcoal filters are saturated Replace the activated charcoal fil...

Страница 15: ...tion model Activated charcoal filter for recirculation model Long life activated charcoal filter set with plastic receptacle for recirculation model Long life activated charcoal filter for recirculati...

Страница 16: ...535 Air flow at intensive or boost setting Qboost m3 h 720 Airborne acoustical A weighted Sound Power Emissions at minimum speed SPEmin dBA 50 Airborne acoustical A weighted Sound Power Emissions at m...

Страница 17: ...carried out by a qualified electrician Then cut the mains cable off flush with the appliance 8 3 Disposal The crossed out wheeled bin symbol requires the separate collection of waste electrical and e...

Страница 18: ...oving 10 Model designation 2 O Operating elements 8 Operating the appliance 8 Operation 8 P Product fiche 16 Q Queries 19 R Recirculation model 7 Resetting the filter saturation indicator 9 S Safety p...

Страница 19: ...hem on the identification plate of your appliance My appliance information SN __________________________ Appliance ______________________________ Please have this appliance information to hand when co...

Страница 20: ...grease filter saturation indicator for filter Flashing Saturation indicator for activated charcoal filters recirculation model de pending on use Replace standard activated charcoal filters Clean and...

Отзывы: