10 Technical data
69
10.2 Noise measurement
The measurement is to be carried out in accordance with the European Norm
on airborne acoustical noise IEC 60704.
➤
Install the appliance (see Installation Instructions).
➤
For relevant appliances, screw the slide plate to the floor at the front and
back.
➤
Feed the inlet and drain hose into and then out of the test cabinet (see
Installation Instructions). Seal the opening around the hoses and cable in
accordance with the norm.
➤
Fit a 19 mm thick chipboard (density: >750 kg/m³) to the appliance door
as a decorative plate. The decorative plate must reach down to the floor,
with an air gap of max. 2 mm. The lateral distance may not exceed 2 mm.
Appliances with an adjustable plinth are built in without this.
➤
To level out any unevenness between the test cabinet and the floor, seal
any gaps between them.
➤
As described in the norm, the measurement is to be carried out without
detergent and rinse agent. Turn rinse agent dosage off (see
U
SER
SETTINGS
).
➤
First, completely fill the salt reservoir with water and then add the regener-
ation salt (see
C
ARE
AND
MAINTENANCE
).
➤
The appliance regenerates periodically. This extends the life of the
appliance, but has no significant effect on the noise measurement.
➤
Set the water hardness setting (see
U
SER
SETTINGS
).
Please note the Installation Instructions accompanying the appliance.