background image

Installation instructions

Oven / CombiSteam oven
Construction type 60-600

J32A.113-0

26.11.11  WIMA

2

Installation for niche height of 600 mm

1. Slide appliance approx. 19 cm into the niche.  Caution: danger of tipping over!
2. Pivot connection box 

D

 downwards after loosening screw 

S1

.

3. Draw connection cable 

H

 from the point where it leaves the wall and through hole 

L

 and press firmly on snap lock clamp 

E

 to secure 

the strain relief.

4. Connect connection cable to connecting terminal 

G

 in accordance with connection plate 

F

.

5. Pivot connection box 

D

 upwards and fasten with screws 

S1

.

6. Slide appliance into the niche until flush with the front and fasten the sides from the front with the 4 enclosed screws 

S2

.

Installation variant for a niche height of 635 mm with adapter frame (see J731.050)

Installation

Open snap lock 

E

 for the strain relief using screwdriver.

=

=

30

min. 550

600

560–568

594

20

X

548

548

S2

598

S2

~45

(567)

440

D

E

S1

G

L

F

~16˚

~85˚

596

H

594

Niche

598

Appliance

Detail X

D

 Connection 

box

E

 Snap 

lock

F

 Connection 

plate

G

 Connection 

terminal

H

 Connection 

cable

L

  Hole for connection cable

S1

  Screw for connection box

S2

  Fastening screws (4×)

598

596

=

=

30

600

560–568

635

20

(567)

548

596

480

35

560

548

19.5

min. 550

Отзывы: