background image

This system have auto-alarm function to ensure the security for the house owner. Total 4 

different sensors were placed to protect different defense area. When the sensor was triggered, 

the monitor will sent out alarm sound immediately and will sent the alarm signal to the guard 

center at the same time. Note that your system may not have all the 4 sensors according to the 

system configuration.

○ Intruction:

9.  Defense Alarm Function(Optional)

Motion Sensor

Delay sensor, normally it 
will be placed on doors 
or windows. If the sensor 
is set, when the door or 
window  is  opened,  the 
monitor  will  sent  out 
alarm sound and sent the 
alarm signal to the guard 
center. 

Infrared Sensor

Delay  sensor,  can  be 
placed  on  living  room 
or  bedrooms. When  the 
sensor is set, if some body 
invade into the defence 
area, the monitor will sent 
out alarm sound and sent 
the  alarm  signal  to  the 
guard center. You can set 
this sensor when nobody 
at home.

Smoke Sensor

24-hour sensor, this sensor 
is opened by the system by 
default. It can be placed on 
living room or kitchens. 
if  any  fire  happened  in 
the area, the monitor will 
sent out alarm sound and 
sent the alarm signal to the 
guard center.

Emergency Help Button

24-hour sensor, this sensor 
is opened by the system by 
default. It can be placed 
any where suitable. if any 
fire happened in the area, 
the monitor will sent out 
the emergency help signal 
to the guard center. 

- 5 -

Содержание C5-AT25/D4

Страница 1: ...English VIDEO INTERCOM SYSTEM USER MANUAL MENU TALK MONITOR Main Menu Monitor Intercom Alarm Function User Setup Close About OK Select Item C5 AT25 D4 Version 1 0 120313 ...

Страница 2: ......

Страница 3: ...reen MENU Button MONITOR Button UNLOCK Button LED Indicator CALL Button TALK Button Speaker Navigation Button Mounting Hook Main Connection Port Mounting Hook 145 160 cm 1 Fix 2 screws to the wall at a appropriate height 2 Connect the system correctly 3 Attach the monitor to the bracket ...

Страница 4: ...alk with the Door Station during monitoring and press UNLOCK to open the door this function is depended on the system configuration 2 Operation Instructions 3 Image and Volume Adjustment During monitoring or talking press MENU Button the ADJUST MENU will be displayed Use Button to select the adjustment item use Button to decrease increase the value 1 The first item is Scene mode selection Total 4 ...

Страница 5: ...p 1 Door Station Call Tone Intercom Call Tone DoorBell Call Tone Date Time Setup Next Page Exit OK Select Item 5 Day Ring Volume Night Ring Volume Setting The ring volume for day time and night time can be set individually 6 00 AM 18 00 PM is the day time by default if you don t want to be disturbed at night you can set the night ring volume to 0 Select User Setup item on main menu page to enter s...

Страница 6: ...When the monitor is in standby mode press CALL Button to enter Intercom Function page or select Intercom item on main menu page Press Button to move upward downward to select the item you want press MENU Button to enter 1 Choose Alarm to Guard Unit item the monitor will send the alarm message to the guard center and show emergency calling 2 Choose Direct Call Guard Unit item the monitor dails the ...

Страница 7: ... out alarm sound and sent the alarm signal to the guard center Infrared Sensor Delay sensor can be placed on living room or bedrooms When the sensor is set if some body invade into the defence area the monitor will sent out alarm sound and sent the alarm signal to the guard center You can set this sensor when nobody at home Smoke Sensor 24 hour sensor this sensor is opened by the system by default...

Страница 8: ...rmed Alarm 8 Exit 3 Out Delay Period after you arm the system you will get into Out Delay Period monitor will sent out short Di every 3 seconds you will hear a long Di at the end of the Out Delay Period and the system is gotten into the protecting status By default the Out Delay Period is 40 seconds users must get out off the room within 40 seconds otherwise the system will treat the user as a inv...

Страница 9: ...ame result as enter Main Menu Alarm Functions menu select Disarm item D Button Use this button to release the door same result as press the Unlock button on monitor 1 Remote control distance is normally up to 30 meters and will extend if the built in telescopic antenna is taken out 2 If the controlled distance is becoming shorter or LED doesn t light on while pressing any button open the remote co...

Страница 10: ...unpredictable damage 1 Don t attempt to service this product yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer servicing to qualified service personnel 2 To prevent fire or shock hazard do not expose this product to rain or moisture 3 Do not install the product where it is exposed to constant sunlight or rain 4 Do not install the product where excess...

Страница 11: ......

Страница 12: ...Please read this manual carefully before using the product you purchase and keep it well for future use We reserve the right to modify the specification in this manual at any time without notice ...

Отзывы: