V-TAC VT-81000 Скачать руководство пользователя страница 4

1.  The load does not work:

a. Please check if the connection of power source and load is correct.

b. Please check if the load is good.

c. Please check if the settings of working light correspond to ambient light.

2.  The sensitivity is poor:

a. Please check if there is any hindrance in front of the detector to affect it to receive the signals.

b. Please check if the ambient temperature is too high.

c. Please check if the induction signal source is in the detection field.

d. Please check if the installation height corresponds to the height required in the instruction.

e. Please check if the moving orientation is correct.

3.  The sensor can not shut off the load automatically:

a. Please check if there is continual signal in the detection field.

b. Please check if the time delay is set to the maximum position.

c. Please check if the power corresponds to the instruction.

SOME PROBLEM AND SOLVED WAY

•  Turn LUX knob anti-clockwise on the minimum (3). If the ambient light is more than 3LUX, 

the sensor would not work and the lamp stop working too. If the ambient light is less than 

3LUX (darkness), the sensor would work. Under no induction signal condition, the sensor 

should stop working within 10sec±3sec.

Note: when testing in daylight, please turn LUX knob to 

 (SUN) position, otherwise the 

sensor lamp could not work! If the lamp is more than 60W, the distance between lamp and 

sensor should be 60cm at least.

Отзывы: