V-TAC VT-6607036 Скачать руководство пользователя страница 32

E

D

tŝ&ŝŽŶŶĞĐƟŽŶ

B

WsŽŶŶĞĐƟŽŶ

C

'ƌŝĚŽŶŶĞĐƟŽŶ

Warning:

 Positive Crimp Contact

Negative Crimp Contact

12-15 mm

12-15 mm

MC

^dKW

!

MC

Note: 

You’ll hear click sound when 
the connector assembly is correct

1

2

3

Note: 

Please use PV connector crimper 
to pinch the point of the arrow

The fatal high voltage may on the DC side, please comply 
with electric safety when connecting.
Please make sure the cable connected in correct polarity 
with inverter, otherwise inverter could be damaged.

Warning:

1. Connect AC terminals and waterproof 
head, tighten the cap, make sure they clip 
closely together. 
2. Connect AC connector to AC terminal of the inverter. 
3. After making sure that it is firmly inserted, tighten the 
sleeve on the AC connector to the right and hear a click.           

1

2

3

7mm

The fatal high voltage may on the AC side, please 
comply with electric safety when connecting.
Please make sure the right line of AC grid connected 
with inverter, otherwise inverter could be damaged.

1

2

3

3

Quick Installation Instructions

SINGLE PHASE INVERTER:

VT-6607036

Fasten

Note: 

PV cable suggestion 
Cross-section
4 mm²

Note: 

AC cable suggestion 
Cross-section
4 mm²

24

25

Af

ŽƌĞ^ŵĂƌƚDĞ

t

Ğƌ

E

ĞƌŽͲ/ŶũĞĐƟŽŶŽŶŶĞĐƟŽŶ

KƉƟŽŶĂů

Version: S06017-01

1

2

Please refer to "Zero Injection 
Smart Meter Installation and 
Operation Manual" for detailed 
instruction.

Note: 

Please follow below pin order
RS485A(Pin 7) to single-phase meter (Pin 24)
RS485B(Pin 8) to single-phase meter (Pin 25)

Note: 

24

25

1-6

7
8

PIN

Assignment

RS485 A  ( 24 )
RS485 B  ( 25 )

/

Zero-Injection Port pin assignment

12345678

RJ45 Plug

^ŵĂƌƚDĞƚĞƌ

Turn on the DC switch and AC 
circuit breaker, wait until the LED 
on the monitoring module flashes.

Configure the Monitor Module, 
router, account registration, etc. 
Please check the WiFi connection 
manual for details.

Scan the QR code below 

to view the user manual

^ŵĂƌƚDĞƚĞƌ

Scan code download APP

Home version

PRO version

Содержание VT-6607036

Страница 1: ...ate of purchase The warranty does not apply to damage caused by incorrect installation or abnormal wear and tear The company gives no warranty against damage to any surface due to incorrect removal an...

Страница 2: ...cessories are disposed of in accordance with appli cable regulations 7 VTAC inverter should be placed upwards and handled with care in delivery Pay attention to waterproof Do not expose the inverter d...

Страница 3: ...lead to device malfunction or damage Do not dispose of this device with the normal domestic waste Without transformer This inverter does not use transformer for the isolation function Refer to manual...

Страница 4: ...om 0 8 leading to 0 8 lagging Output Current THD 3 EFFICIENCY VT 6607036 Max Efficiency 98 20 Euro Efficiency 97 82 PROTECTION VT 6607036 PV Reverse Polarity Protection Yes PV Insulation Resistance De...

Страница 5: ...0 100 Topology Transformerless Communication Interface RS485 WiFi Wire Ethernet GPRS optional Cooling Concept Convection Noise Emission db 28 Night Power Consumption W 1 Max Operation Altitude m 4000...

Страница 6: ...ing list shown as below Unpacking Package List Quick Installation Insructions Monitor Quick Installation Instructions No Qty Items No Qty Items 1 1 Solar inverter 8 3 Plastic Expansion Tube 2 1 Certif...

Страница 7: ...Product Overview Inverter Terminals No Items No Items 1 DC Switch 5 Monitor Module Port 2 DC Connectors For PV Strings 6 Zero Injection Port Optional 3 DC Connectors For PV Strings 4 AC Connector...

Страница 8: ...olid surface far from flammable or corrosion materials where is suitable for inverter s weight and dimensions The ambient temperature should be within 25 C 60 C between 13 F and 140 F The installation...

Страница 9: ...Mounting STEP 1 STEP 2 Leave the enough space around inverter easy for accessing to the inverter connection points and maintenance...

Страница 10: ...ach MPPT channel is correctly connected with PV string Other wise the inverter will activate voltage or current protection automatically Please make sure below requirements are followed The open circu...

Страница 11: ...tive Crimp Contact Note Note You ll hear click sound when the connector assembly is correct Please use PV connector crimper to pinch the point of the arrow Positive Crimp Contact STEP 3 Note PV String...

Страница 12: ...ble range of the inverters The phase line from AC distribution box are correctly connected Use the AC plugs in the accessory The surge protector should be equipped between grid and inverter Disconnect...

Страница 13: ...2 Connect AC connector to AC terminal of the inverter 3 Afeer making sure that it is firmly insered tighten the sleeve on the AC connector to the right and hear a click Note AC line goes through AC t...

Страница 14: ...monitoring module could transmit the data to the cloud server and display the data on the PC tablet and smart phone WIFI Ethernet GPRS RS485 communication is applicable to the inverter Please refer to...

Страница 15: ...o the inverter through RS485 communication to ensure that the power of the inverter is less than or equal to the user s home load and no current flows into the grid STEP 1 STEP 1 Note Note For single...

Страница 16: ...ontrol Panel No Items No Items 1 LCD Display 5 ENT Touch Button 2 UP Touch Button 6 POWER LED Indicator 3 DOWN Touch Button 7 GRID LED Indicator 4 ESC Touch Button 8 FAULT LED Indicator Weather Statio...

Страница 17: ...The inverter is stand by OFF The inverter is power off GRID ON Green The inverter is feeding power OFF The inverter is not feeding power FAULT ON Red Fault occurred OFF No fault Menu Structure First L...

Страница 18: ...f inverter including date and time Wifi Info Display the WIFI serial number and assigned IP address Date Time Set date and time of the inverter Setting Set the protection parameters of inverter Functi...

Страница 19: ...ge lower limit UP DOWN Choose PassWord xxxx UP DOWN choose Setting UP DOWN choose Freq Range UP DOWN choose PassWord xxxx UP DOWN set protection time UP DOWN set level 2 frequency upper limit protecti...

Страница 20: ...he public grid Turn on the DC switch on the inverter Turn on the PV switch of the system Turn off the DC switch on the inverter Turn off the DC switch between PV panels and the inverter if any Close t...

Страница 21: ...ly and frequently please ask help for local distributors PV2 Over Current PV2 current is too high protection is triggered Grid Fault Island Fault The public grid is outage or the grid is disconnect ed...

Страница 22: ...y please ask help for local distributors The temperature of the CPU is high that beyond the protection range Auto Test Fail Automatic test failed Power off the inverter to check the AC connection then...

Страница 23: ...is objects which block ing the fan rotation and remove it Eeprom Fault Eeprom abnormal Power off then restart Ref Chapter6 If fault still occurs continuously and frequently please ask help for local d...

Страница 24: ...gh London UK Postcode SL1 6BW Thank you for selecting and buying V TAC Product V TAC will serve you the best Please read these instructions carefully keep this user manual handy for future reference I...

Страница 25: ...therwise agreed herein this manual will only be used as guidance Any statement information or suggestion in this manual will not take any form of responsibility Without written permission any content...

Страница 26: ...ove the Module 1 WIFI MODULE INSTALLATION Implication Lights Status Description All lights are single green lights Communication with router Communication with inverter WIFI Module running status 1 Li...

Страница 27: ...cess to the network 2 Check the router s setting if the connection is limited 3 Contact our customer service 1 Check the connection between WIFI Module and inverter Remove the WIFI Module and install...

Страница 28: ...ethods and key press descriptions for Reset button NOTICES FOR RESET BUTTON USER MANUAL FOR SOLARMAN SMART APP Notice Do not remove waterproof plug Key press Status Descrip on Light Status Short press...

Страница 29: ...packaging or on the logger body 4 Network Configuration After the logger is added please configure the network to ensure normal operation Go to Plant Details Device List find the target SN and click...

Страница 30: ...check plant data Usually the data will be updated in 10 mins If configuration failure occurs please check the following reason and try it again 1 Make sure WLAN is ON 2 Make sure WiFi is normal 3 Make...

Страница 31: ...make sure each MPPT channel connect with a PV string separately Otherwise the inverter will activate voltage or automatic current protection PV Array 1 PV PV PV PV PV Array 2 PV Inverter The followin...

Страница 32: ...electric safety when connecting Please make sure the right line of AC grid connected with inverter otherwise inverter could be damaged 1 2 3 3 Quick Installation Instructions SINGLE PHASE INVERTER VT...