background image

Replace fuse/lamp only with the same type.
In the event of serious operating problem, stop using the unit immediately.
Never turn on and off the unit time after time.
The housing, the lenses, or the ultraviolet filter must be replaced if they are
visibly damaged.
DO NOT attempt to operate this unit if it becomes damaged. DO NOT attempt
any repairs
yourself. Repairs carried out by unskilled people can lead to damage or
malfunction. Please contact the nearest authorized technical assistance center
if needed.
Disconnect this product from its power source before servicing.
DO use the original packaging if the device is to be transported.
Avoid direct eye exposure to the light source while the product is on.
Never touch bulb with bare fingers, as it is very hot after using.
DO NOT operate this product if you see damage on the housing, shields, or
cables. Have the damaged parts replaced by an authorized technician at once

Installation:

The fixture should be fixed on the clamp. Always ensure that the unit is firmly
fixed to avoid vibration and slipping off during operation. Ensure that the
trussing or area of installation must be able to hold 10 times the weight without
any deformation. Always install a safety cable that can hold at least 12 times
the weight of the fixture when installing.DO install and operate by qualified
operator. It must be installed in a place where there is out of the reach of
people.

2.INSTALLATIONS

installations Note: In order to increase protection, please install the lamp on

the sidewalk, outside the seating area, or an area where unauthorized persons
may touch the lamp
Before installing the fixture on any surface, make sure that the installation area
can bear the minimum point load above 10

points of the weight of the

equipment. The installation of the fixing device must always be fixed with
auxiliary safety accessories (such as a suitable safety rope)
Do not stand directly under the equipment when installing, removing, or
servicing fixtures
From the ceiling or set on a flat surface (see the picture below). Ensure that
this fixture is kept at least 0.5m (1.5 feet) away from any flammable materials
(decorations, etc.)
Be sure to use and install the supplied safety rope to ensure safety and

Содержание T918 Guardian

Страница 1: ...T918 Guardian User Manual...

Страница 2: ...quate ventilation at least 50cm from adjacent surfaces Be sure that no ventilation slots is blocked otherwise the unit will be overheated Before operation ensure that you are connecting this product t...

Страница 3: ...fixed to avoid vibration and slipping off during operation Ensure that the trussing or area of installation must be able to hold 10 times the weight without any deformation Always install a safety ca...

Страница 4: ...bracket and use the M10 screw that passes through the center hole of the bracket to fix it As an additional safety measure make sure to use at least one safety cable integrated in the base assembly to...

Страница 5: ...the UP DOWN button to select DMX Address press the ENTER button to confirm the present address will blink in the display use the UP DOWN button to adjust the address from 001 to 512 press the ENTER b...

Страница 6: ...5 Fixture size 6 Illuminance chart...

Страница 7: ...7 Effect Wheels color wheel Gobo wheel...

Страница 8: ...ter with smooth wash effect DMX Channel 21CH Operate mode DMX512 self propelled master slave Sound active RDM Fixture size 303 226 405mm Net weight 10 KG contains Folding clamp Features 1 Electric foc...

Страница 9: ...press the menu key one or more times to return to the main interface 2 In the main interface press the Up key or the Down key to select the Settings button 3 Press the OK button to enter the Settings...

Страница 10: ...editing Press again to exit the editing state Motor reset close open Led reset channel mode Standard 21CH Standard 21 channel mode X reverse close open Y reversal close open XY swap close open Swap t...

Страница 11: ...tton to clear the error record total usage time This time of use temperatur e Display the current temperature of the lamp bead 10 4system Option Description DIS Dashboard software version MT Motor boa...

Страница 12: ...failed The color wheel Hall or the color wheel motor has a problem Pattern disk reset failed Gobo Hall or gobo motor is faulty Focus reset failed Focusing Hall or there is a problem with the focusing...

Страница 13: ...9 color 9 color 9 color 10 color 10 Color 10 Color 11 color 11 Color 11 Color 12 color 12 Color 12 Color 13 color 13 Color 13 Color 14 color 14 Color 14 white light Reverse flow from fast to slow For...

Страница 14: ...fast Gobo18shock from slow to fast Forward flow from fast to slow Reverse flow slow to fast 10 Frost 000 127 128 255 no frost cut 11 Prism 000 127 128 255 Prism pops up Prism cut 12 Prism rotation 00...

Страница 15: ...gh quality shielded twisted pair Connect a signal terminating resistor 120 ohms at the end of the fixture Lighting does not start Check whether the parameters of the power supply are consistent with t...

Отзывы: