Copyright @ 2013 V-chip Microsystems,Inc
Version: VTDTMUA5-MARCH-2013 v5.0
VT-DTMUA5-433
“Radio Baud:03”: Radio band setting value
“Radio Channel:03”: Radio Channel setting value
Fig 6 Parameter Collect
Setting Command
All Commands are used HEX format, and the command format is:
Data
SOF
CMD
PLOAD
EOF
Length(byte)
1
1
n
1
Functions
Start Byte
Command Byte
Data Byte
Stop Byte
SOF: Start byte, 0xFD
;
CMD: Command byte, indicate different command
;
PLOAD: Data bytes, configure content
;
EOF: Stop byte, 0xFE
。
CMD 1: Enter Setting Mode
If enter setting mode and then set the parameters, the setting parameters will be stored.
Data
SOF
CMD
EN1
EN2
EN3
EN4
EN5
EOF
Length(byte)
1
1
1
1
1
1
1
1
Functions
0xFD
0x00
0x55
0x55
0x55
0x55
0x55
0xFE
Respond:
Data
SOF
CMD
STATE
EOF
Length(byte)
1
1
1
1
Functions
0xFD
0x00
0 Success; non-0 Fail
0xFE
CMD 2: Exit Setting Mode
Data
SOF
CMD
EN1
EN2
EN3
EN4
EN5
EOF
Length(byte)
1
1
1
1
1
1
1
1
Functions
0xFD
0xFF
0xAA
0xAA
0xAA
0xAA
0xAA
0xFE