To avoid downtime and to make sure that the safety of the vacuum cleaner is intact, it is recommended that an
authorized service technician inspect the electrical parts annually.
Check / Maintenance of the Machine
Description
Before/after use
Month / Year Hours
Check / replacement of motor
700
Safety check of the machine
Yearly
Emptying and cleaning
After use (as required)
Check of filters and machine in general
Before use
Check of cord and plugs
Before use
Check of alarm (lamp)
Before use
Reordering Collection Container incl. HEPA Filter:
Collection container incl. HEPA filter
84.16.0001
Trouble Shooting
If the machine does not vacuum satisfactorily:
Hose, pipe or nozzle may be blocked, or the blanking plug is fitted.
Stop the machine and remove the blocking or the blanking plug.
The collection container may be full.
Stop the machine and replace the container. See the relevant section.
A leak may have occurred when fitting the collection container.
Start the machine and block the hose. Normally you will be able to hear a possible leak. Loosen the clips of
the collection container, check the gasket at the bottom of the container, place the container onto the vacuum
cleaner again and close the clips to fasten it.
The HEPA filter may be blocked.
Replace the collection container incl. HEPA filter as described in the corresponding section.
Thermal overload activated:
The machine is not getting enough cooling air and is automatically cut off.
Let the motor cool and resolve the cause of the overload (see above).
Any repairs and service on the vacuum cleaner must be carried out by V. BRØNDUM A/S, an authorized dealer