![UWT Vibranivo VN 4000 Series Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/uwt/vibranivo-vn-4000-series/vibranivo-vn-4000-series_technical-information-instruction-manual_1066148014.webp)
Level limit switch
Series VN 4000
Technical Information / Instruction manual
page G
Signal output
FSL / FSH Setting
If the sensor is used to indicate full load, set to
Fail Safe High.
Power failure or line break is regarded as „full“
signal (protection against overcharging).
If the sensor is used to indicate empty load, set
to Fail Safe Low. Power failure or line break is
regarded as „empty“ signal (protection against
running dry).
FSH
FSL
Signal output
Signal output
Signal output
Setting
Relay DTPT
3-wire PNP
LED “Signal output”
LED „Signal
output“
Setting
“FSL / FSH”
Vibranivo
®
1
2
3
4
5
6
7
8
9
10
11
12
VN 4000 a
gi161213
14
FSL
FSH
FSL
FSH
FSL
FSH