Level limit switch
Series RN 4000
Technical information / Instruction manual
Operating conditions
Ambient temp. (housing)
-20 .. +60°C (-4 .. +140°F)
-40 .. +60°C (-40 .. +140°F) Version with heating of housing (pos.26)
Process temperature
-20 .. + 80°C (-4 .. +176°F)
-40 .. +80°C (-40 .. +176°F) Version with heating of housing (pos.26)
Ventilation
Ventilation is not required
Min. powder density/
Sensitivity
see section “Sensitivity” on page 17
Signal delay
Version
AC, DC, Multivoltage
Universal voltage
Sensor free -> covered*
ca. 1.3 sec
ca. 1.5 sec + 0 .. 20 sec adjustable
Sensor covered -> free
ca. 0.2 sec
ca. 0.2 sec + 0 .. 60 sec adjustable
*after blocking of the measuring vane
Features of bulk material
Hardly any limitations
Max. permitted mechanical
torque (lateral)
Process connection aluminium:
max. 50 Nm
Process connection plastics:
max. 25 Nm
Protective measures in case of high loading: mounting of an protective canopy above the probe.
Max. tractive force
Pendulum shaft:
400 N (applicable only as full detector)
Rope extension:
1.5 kN (applicable only as full detector)
Max. process pressure
-0.9 .. +0.8 bar (-13.1 .. +11.6 psi)
Versions with Ex-approvals: see remarks on page 19.
Vibration
1.5 (m/s
2
)
2
/Hz according to EN 60068-2-64
Relative Humidity
0 - 100%, suitable for outdoor use
Altitude
max. 2,000 m (6,562 ft)
Expected product lifetime
Following parameters have a negative influence on the expected product lifetime:
High ambient- and process temperature, corrosive environment, high vibration, high flow rate of
abrassive bulk material passing the sensor element, high amount of measurement cycles.
Technical Data
Transport and Storage
Transport
Observe the instructions as stated on the transport packaging, otherwise the products may get
damaged.
Transport temperature: -40 .. +80°C (-40 .. +176°F)
Transport humidity: 20 .. 85%
Transport incoming inspections must be caried out to check for possible transport damage.
Storage
Products must be stored at a dry and clean place. They must be protected from influence of corrosive
environment, vibration and exposure to direct sunlight.
Storage temperature: -40 .. +80°C (-40 .. +176°F)
Storage humidity: 20 .. 85%