Level limit switch
Series CN 4000
Technical Information / Instruction manual
page
Mounting
A
Full detector horizontal or oblique.
Slight incline mounting helps remaining material to fall
off more easily.
B
Demand or empty detector horizontal or oblique.
Slight incline mounting helps remaining material to fall
off more easily. Protective angle recommended
depending on load and abrasion of the material.
C
Empty detector oblique from the bottom.
D
Empty detector in the silo outlet.
CN 4020
CN 4030
CN 4050
A
Full detector vertical.
B
Full detector with sliding sleve.
C
Full detector horizontal or oblique. Slight incline
mounting helps remaining material to fall off more
easily.
D
Demand or empty detector horizontal or oblique.
Slight incline mounting helps remaining material to fall
off more easily. Protective angle recommended
depending on load and abrasion of the material.
CAUTION
Observe:
• General distances of the probe (see page 11).
• Distance to material flow (filling).
• Max. permitted mechanical load (see page 8).
• Wearing due to abrasive bulk material.
A
Full, demand or empty detector vertical.
CAUTION
Observe:
• General distances of the probe (see page 11).
• Distance to material flow (filling).
• Max. permitted mechanical load (see page 8).
• Wearing due to abrasive bulk material.
CAUTION
Observe:
• Distance of the probe to the silo wall (see page 11).
Consider that the hanging probe can move sidewards
with material.
• Distance to material flow (filling).
• Max. permitted mechanical traction (see page 8).
Empty detector: Do not install in the center of the silo
due to high traction with moving material.
• Wearing due to abrasive bulk material.
Capanivo
®
1
2
3
4
5
6
7
8
9
10
11
12
CN 4000
gi011217