Refer to Appendix A for minimum
weight required.
NOTE
: Details of every transaction
transmitted will be stored in memory.
Press
MODE
to transmit the total value
accumulated to printer.
NOTE
: The data stored in memory will be erased:
a.
when
MODE
is pressed, or
b.
when scale is turned off, or
c.
when weight unit is changed.
Fun-20Set RS232 data format. Three formats
are available:
00 = Format 0 (Default)
01 = Format 1
02 = Format 2
Refer to Appendix B for individual
transmission format.
Fun-21Set Printer data format
00 = Format (Default)
01 = Format (Mot available)
Refer to Appendix C for printout format.
Fun-30Set Weight Check Beep Mode
Beep 0: No alarm output, (Default)
Beep 1: Alarm when weight detected
falls within the upper and lower
limit.
Beep 2: Alarm when weight detected
exceeds the upper limit or below
the lower limit.
Beep 3: Alarm when weight detected
exceeds the upper limit.
Beep 4: Alarm when weight detected is
below the low limit.
7.OPERATING INSTRUCTION
7.1
PLACING THE SCALE
Place this scale on a hard and strong
enough surface where is free from RF
interference, vibration, fire, direct
sunlight and excessive moisture.