UWE BW-150 Скачать руководство пользователя страница 6

b. To employ (disable) the Auto Hold Function, 

press and hold 

RECALL/SET

 until “b.- 150” and 

5 arrows beneath appears(disappears). 

c. Release 

RECALL/SET 

and scale will return 

to normal operation status. 

4.4 TO TARE OFF THE WEIGHT OF A CONTAINER/ SET 

WEIGHT TO ZERO 

4.4.1

 Place a container onto the platform, 

then press and hold FUNCTION until zero weight 

is displayed. 

4.4.2 To Clear Container Weight from Memory 

To clear the weight of the container stored, 

remove the container and all loads from the 

platform. Press and hold FUNCTION until zero 

weight displayed. 

4.4.3

 Zero the weight value is not displayed 

when the scale is unloaded, press and hold 

FUNCTION to reset weight to zero. 

4.5 WHEN WEIGHING 

Always apply load to the platform gently. 

Sudden shock/excessive force may cause damage 

to the weight sensor inside. It is a good 

practice to remove all the loads from platform 

immediately after weighed. This would prolong 

the life time of the weight sensor. 

4.6 HOLDING A WEIGHT DISPLAYED 

4.6.1 

When Auto Hold Function is not employed 

Press 

RECALL/SET

 to employ the Auto Hold 

Function. 

4.6.2

 When Auto Hold Function is employed 

After Auto load is stable, the scale 

would automatically retain the weight 

displayed. 5 flashing arrows beneath the 

weight would appear indicating the 

weight displayed is being held. Weight 

retained would be released 

automatically 3 seconds after load is 

removed. 

4.7 SELECT BACKLIGHT (option) STATUS 

The default setting of backlight is on. 

Backlight would automatically go off 5 

second after zero weight is detected and 

automatically turned on immediately 

when a load is detected. 

 

To enable/disable backlight function,

 press and hold ENTER unit the desired 

status is attained. 

4.8 MEMORY FUNCTION 

4.8.1

 

Save Actual Weight to Memory

. For actual 

weight entry range, refer to GENERAL AND 

OPERATIONAL SPECIFICATIONS 

1. Select the appropriate weight unit. 

Содержание BW-150

Страница 1: ...BEFORE ATTEMPT TO OPERATE THE SCALE AUGUST 1999 REV 2 Specifications subject to change without prior notice CONTENTS 1 INSTALLATION 2 SPECIFICATIONS 3 KEYBOARD LAYOUT AND DESCRIPTION 4 INSTRUCTIONS FOR USE 5 TROUBLE SHOOTING 6 DAILY CARE AND MAINTENANCE 7 INSTALLATION DIAGRAMS ...

Страница 2: ... the W shape support with the front of the indicator against the platform 1 3 2 Wall Mount 1 3 2 1 Install the supplied U shape support to a strong wall surface Secure the support to the wall with screws supplied In no circumstance the extended cable length should excess 100 cm Connect the cable plug from the platform to the indicator receiving plug 1 3 2 2 Connect the cable plug from the platform...

Страница 3: ...OPERATIONAL SPECIFICATIONS MODEL BW 150 FREEWEIGHT Capacity 150kg 330lb Graduation 0 10kg 20g 10 20kg 50g 20 150kg 100g 0 330lb 0 2lb 0 330lb 2oz Weight Unit Power Source 1 kg 2 lb lb 3 lb oz 4 X UM1 Battery Size D Alkaline Battery or AC DC Power Adaptor DC 9V 100mA Battery Operation Time 500 hours w o backlight Platform Size 280 x 330mm Net Weight 4 5kg Gross Weight 5 5kg Auto Hold Range WT 20kg ...

Страница 4: ...UND UNITS WOULD BE DISABLE IN CERTAIN COUNTRIES PLEASE CONTACT YOUR LOCAL FOR MORE INFORMATION SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE KEYBOARD LAYOUT DIAGRAM SYMBOLS DESCRIPTION 3 KEYBOARD LAYOUT AND DESCRIPTION ...

Страница 5: ...it kg indicates the metric weight unit is being employed lb indicates the pound weight units are being employed 4 INSTRUCTIONS FOR USE 4 1 PLACING SCALE Use this unit only on a hard and strong surface where is free from RF interference vibration fire direct sunlight and excessive moisture 4 2 POWER THE SCALE Press ON OFF to turn scale on 4 3 INTERNAL SETTINGS 4 3 1 Select Weight Unit This unit is ...

Страница 6: ...to remove all the loads from platform immediately after weighed This would prolong the life time of the weight sensor 4 6 HOLDING A WEIGHT DISPLAYED 4 6 1 When Auto Hold Function is not employed Press RECALL SET to employ the Auto Hold Function 4 6 2 When Auto Hold Function is employed After Auto load is stable the scale would automatically retain the weight displayed 5 flashing arrows beneath the...

Страница 7: ...E 1 Each of the MEM key could store by actual weight or target weight entry one value of each weight unit 2 Weight stored in memory will not be erased when power off 4 8 3 Recall Weight Stored 1 Select the appropriate weight unit 2 Press MEM 1 to MEM 5 to recall weight stored 3 Scale displays memorized weight and will return to normal operation status after 3 seconds 4 8 4 Weight Gained or Lost Co...

Страница 8: ... batteries into the battery pack underneath the platform with polarity as shown inside the battery pack 5 TROUBLE SHOOTING SYNDROME CHECK ACTION SCALE CANNOT BE TURNED ON Are batteries inserted properly Check batteries insertion Is the main adapter inserted properly both to the wall outlet Is the output plug of the main adapter inserted properly into the DC inlet of the scale Secure both ends of t...

Страница 9: ...he weight of load excesses the maximum capacity of the scale Removed loads on platform and check again SCALE AUTOMATICALLY TURNED OFF AFTER TURNED ON Are battery voltage too low Replace all batteries with new ones SHOWS WHEN SCALE IS TURNED ON Are battery voltage too low Replace all batteries with new ones 6 DAILY CARE AND MAINTENANCE 6 1 Clean the scale with a soft and damp cloth if necessary wit...

Страница 10: ...7 INSTALLATION DIAGRAMS Diagram 1 Batteries installation Diagram 2 W shape mounting Diagram 3 U shape wall mounting Diagram 4 Pillar mounting ...

Страница 11: ...Diagram 5 Pillar mounting accessories ...

Отзывы: