The ON/OFF mode allows the user to control the activation and the deactivation of the UV light emission manually
thanks to the potentiometer, the START button, and the STOP button on the front panel. It also allows the user to
control the UV LED lamp thanks to a PLC.
1.
Manually:
•
Verify that the two “schunt” connectors are plugged on “chiller” and “PLC” M12 5pins connectors
at the
back panel.
•
Choose the UV light intensity between 20% and 99% thanks to the potentiometer.
•
Launch UV light emission by pushing the START button and press START again to stop it.
•
Press STOP to switch off the light in case of an emergency. When this button is engaged, you must disengage
it to allow UV light emission.
2.
With a PLC:
•
Verify that the “chiller” security is not
activated (water circulation)
or use a “schunt” connector on the
“chiller” M12 5 pins connector at the back panel.
•
Choose the UV light intensity between 20% and 99% thanks to the potentiometer.
•
Press START to allow future UV light emission.
•
The PLC can switch on or off
UV light emission thanks to the dry contact between pin1 and pin3 on the “PLC”
M12 connector at the back panel (please refer to the electrical scheme of page 6).
•
Press STOP to switch off the light in case of an emergency. When this button is engaged, you must disengage
it to allow UV light emission.
ON/OFF MODE