9
II System and operation
II UWATEC
®
Smart dive computers
To use the push buttons TEC must be switched on. Operation of the push
buttons is divided into «press» and «press and hold (1 second)».
The push buttons
,
and
activate the following functions:
Select the gas mixture (press)
Confirm the gas mixture (press and hold)
Activate the timer for safety stops (dive mode only, in depths < 6.5 m /
20 ft) (press)
Operate the stopwatch (gauge mode only) (press)
Set a bookmark (press)
Toggle between maximum depth > temperature > MB level > …
(press)
Intermediate time and reset (in gauge mode only and while stop-
watch is active) (press)
Switching on the backlight (press and hold)
2.2 SmartTRAK
With SmartTRAK you can transfer dive data to a personal computer and graphically display the data.
The following settings may be changed with SmartTRAK:
• Unit system
metric/imperial
• Audible attention signal suppression
selective
• Gauge mode
• Depth alarm
5 - 100 m (20 - 330 feet)
• Backlight illumination duration
2-12 sec.
• Maximum partial pressure of oxygen (ppO
2 max
)
1-1.95 bar
• Time limit to reset the O
2
% mix to air
no reset / 1 - 48 hrs.
• Minimum reserve pressure at the end
of the dive (basis for RBT calculation)
20 – 120 bar (300 - 1750 psi)
• Tank pressure alarm
50 - 200 bar (750 - 2900 psi)
•
Replace audible RBT alarm by audible attention signal
• Workload sensitivity
25 steps
• Safety stop duration
1-5 min.
The following data may be recalled with SmartTRAK:
• Number of past dives
• Total duration of past dives
• Atmospheric pressure
• Pairing information from up to 3 transmitters
• Dive profile
• Logbook
• Temperature curve
• Workload curve
• Alarms and attention messages
• Bookmarks
II
English
Push buttons