SCUBAPRO MK 25/MK 20 First Stages
2003 SCUBAPRO
Important note
: The following information is not designed to be a complete training guide for servicing the listed SCUBAPRO regulators. All SCUBAPRO
technicians are required to attend an annual service training program to insure safe handling and servicing of SCUBAPRO products. All SCUBAPRO technicians
must be employed by an authorized SCUBAPRO facility.
6
P/N
43
04
00
00
TOOLS
NEEDED
No tools needed
this step
Separate the cap from the regulator
body. Carefully remove the piston
assembly and spring.
Use the brass pick (blunt end) to
carefully push the piston stem o’ring
assembly from the regulator body.
7/32”
5/32”
Use a 7/32” hex wrench to remove the
swivel retainer from the regulator cap.
Use a 5/32” hex wrench to remove the
low-pressure plugs.