background image

I.    In handheld mode, there are “handheld manual" mode and  “handheld automatic" mode:
1.   “handheld manual” mode
•    In any state, long press the hand-held mode switch for more than 1.5 seconds without releasing your 

hand, enter the hand-held manual mode

•    The UVC LEDs start to work directly, the screen displays “          ", and it will be turned off directly after 

releasing the handheld mode switch

•    In this mode, the fixed mode switch is invalid
2.  "handheld automatic" mode
•    In the light-off or fixed mode, double-click the handheld mode switch to enter the handheld automatic 

mode

•    The preset time for this mode is 60 minutes
•    If the object being disinfected is not detected by the REV-ODS system (the sensing distance will be 

slightly different depending on the surface of the object), the disinfection work will be automatically 
suspended. The “         " on the screen is displayed without flashing, “             " icon disappeared, the 
purple icon “         " will be changed to black icon “         ", If the REV-ODS system does not detect the 
disinfected object for 2 minutes, it will automatically shut down, saving energy and protecting the 
environment.

•    If the REV-ODS system detects the disinfected object, it will automatically resume the disinfection 

work, The “         " on the screen is displayed with flashing, and icon “              " appears, the black icon

     “         " will be changed to purple icon “         ".
•    Short press or double-click the handheld mode switch during the work process to directly shut down, 

the fixed mode switch is invalid

•    When the icon “         " disappears on the screen and the time is displayed as a green number 0: if you 

do nothing, it will automatically shut down after 30 seconds, saving energy and protecting the 
environment; if you short press or long press the handheld mode switch, you can also shut down the 
light.

II.   Fixed Usage of Disinfection Bar. (Available to select the ULTRAVIOLET mode or OZONE mode for 

disinfection).

1.   Short press the switch of fixed mode “         ” to start up. Meanwhile, the intelligent HBS system will 

automatically start. It will automatically switch off after 30 seconds if not performing any operation for 
the energy conservation and environment protection. 

2.  Short press the switch of fixed mode “         ” again to select the disinfection mode: ultraviolet 

disinfection for 10 minutes (the screen displays “          ” ), ultraviolet disinfection for 20 minutes (the 
screen displays “          ” ), ozone disinfection for 70 minutes (the screen displays “         ” ). 

3.  During ultraviolet mode, long press, long press the switch of fixed mode “         ” for 1.5 seconds, and 

the device will enter to the 30-second preparation phase, and the screen will display “         ” (without 
flashing). During ozone mode, long press the switch of fixed mode “         ” for 1.5 seconds to choose 
weak ozone step (intermittent work), for 5 seconds to choose strong ozone step (uninterrupted work, 
screen will display “         ” ), after the selection, device will enter to the 30-second preparation phase.

•    If the intelligent HBS system doesn’t detect any person, the disinfection bar starts to disinfect after the 

30-second preparation phase, and “         ” on the screen starts to flash. It will start to count down,

     “         ” , “          ” or “          ” will respectively change to “         ” , “          ” or “          ”
•    If the intelligent HBS system detects the person, the screen will display “           ” , “         ” will display 

no flash and the disinfection bar stops the work; After continuing for 2 minutes, the disinfection 

Operation Instruction:

UVC

UVC

UVC

Содержание UVP201R

Страница 1: ... ULTIMATE Center Irradiance 13500μW cm Sensor angle 80 Sensor distance 3m REV ODS Reverse Obstacle Detection System 2cm Sensor distance HBS Human body sensing system 7 3V 4000 mAh Li ion UV 2 5 3h O3 9 10h Input Output 5V 2A Work light specifications In Bag UVC Light germicidal system intends for use in general purpose ...

Страница 2: ...y independently hand held using it is usually able to kill 98 56 99 99 bacteria and virus on the surface or articles within 3 seconds During the fixed mode using ozone disinfection has two steps weak ozone and strong ozone Weak ozone step is designed to eliminate odor and formaldehyde in non confined space e g shoe cabinet wardrobe Strong ozone step is applicable to the disinfection in confined sp...

Страница 3: ...hing it will automatically shut down after 30 seconds saving energy and protecting the environment if you short press or long press the handheld mode switch you can also shut down the light II Fixed Usage of Disinfection Bar Available to select the ULTRAVIOLET mode or OZONE mode for disinfection 1 Short press the switch of fixed mode to start up Meanwhile the intelligent HBS system will automatica...

Страница 4: ...ctural degradation of plastic materials 2 Ultraviolet light can cause color shift or structural degradation of resin materials 3 Ultraviolet light can cause color shift or structural degradation of leatherwear 4 Ultraviolet light can cause color shift or structural degradation of organic compounds materials OZONE Equipment Damage Hazard 1 OZONE can cause color shift or structural degradation of pl...

Страница 5: ... poisonous range The odor of ozone is not a reliable warning indicator due to the possibility of olfactory fatigue 9 Long term occupied enclosed spaces such as houses apartments hospitals and offices should have ozone volumes below 0 1mg m 0 05PPM The ozone concentration in the workplace i e occupational exposure limit is 0 1PPM 10 The amount of space used by the equipment used to place and use th...

Страница 6: ...d object it is recommended that In order to achieve the radiation dose of 10 000 μW cm to meet the general needs of daily use the exposure time should be at least above 1 4 seconds In order to achieve the radiation dose of 100 000 μW cm to meet the needs of the professional environment the exposure time should be at least above 500 seconds To guarantee the ozone disinfect effect 1 Ozone can kill b...

Страница 7: ...ABS plastics and no significant decomposition was found 6 It is recommended to avoid ozone disinfection of brightly colored leather silk and other items Some highly aged items such as natural rubber are also recommended to not undergo ozone disinfection Since ozone has an oxidative effect on most metals users should not use ozone disinfection on electronic products to avoid ozone damage to devices...

Страница 8: ...structions WARNING UV C emitted from this product Avoid eye and skin exposure to unshielded product Follow installation instructions and user manual www uvpluss com AEC Lighting Solutions Co Ltd Add 2548 Bao an Highway Jiading District Shanghai 201801 China Tel 400 083 8757 www aeclight reel com ...