Uvitron International SUNRAY 400SM Instruction Manual, Rev. H
Page 5 of 23
INSTALLATION (CONTINUED)
2
The lamp housing assembly can also be placed on a shelf type structure, supporting the unit
by its bottom outside edges. For this type of mounting, a windowed hole must be cut in the
shelf, which would provide adequate clearance for the unit’s bottom-side light exposure
opening, and also for the cooling air exhaust holes.
2.3 Shielding
All installations should incorporate adequate shielding of radiated UV light, in order to prevent
eye and skin burn of the operator or others passing through the work area (refer to UV Safety
Warning in the following Safety Considerations section of the manual). The optional UV0455
Wrap-around Front Flood Shield and the UV1094 Backside Flood Shield can be used with
the SunRay to minimize the amount of stray UV light scattering in the work area. Custom
shielding may be constructed using sheet metal, UV blocking acrylic or polycarbonate to
prevent operator exposure to UV radiation.
WARNING:
To prevent risk of eye or skin burn, all personnel must be protected from
direct or indirect exposure to the UV light produced by the SunRay curing system.
Extreme care should be used when designing custom UV shielding to insure
personnel will not be exposed to harmful UV radiation. Additionally, UV protective
glasses and protective clothing should be used at all times while working in the vicinity
of the UV curing system.
2.4 Dimensions
Fig. 3, SunRay overall dimensions