3.2 Handling batteries 

 

 

When inserting batteries / rechargeable batteries ensure that these are correctly polarized. 

If the device will probably not be needed for a relatively long period of time or if the batteries 
are  empty,  remove  the  batteries;  this  will  prevent  battery  acid  leaking  onto  the  device  and 
damaging it.   

Rechargeable batteries should be recharged as and when necessary. 

You  should  never  attempt  to  recharge  an  ordinary  (non-rechargeable)  battery;  it  may 
explode ! 

Batteries / rechargeable batteries must never be short-circuited or thrown onto the fire.   

Batteries / rechargeable batteries are special waste and must not be discarded together with 
normal domestic waste. 

 
 

4 Introduction 

 
The HI 1 is equipped with a patented connector system. The intelligent connector offers decisive advantages when 
connecting sensors and peripherals because all parameters are stored in an EEPROM located on the connector 
itself; repeat programming is thus no longer necessary.  
 

4.1 Function 

 
The HI 1 measuring instrument has just one measuring input. For operation purposes the device incorporates a 
large LCD display and a keypad.  
 
 

4.2 Sensor programming 

 
The measuring channels are programmed, completely and automatically, by the intelligent connectors.  
 
 

5 Initial commissioning 

 
1.

 Connect sensor 

to socket 

M0

 (1)

2. 

Ensure that the power supply 

is provided by 3 AA batteries; 

3. 

To switch ON 

press key 

 

ON

 

 (3) 

4. 

Select measuring channels 

by pressing key 

 M▲

 (3), read out measured values (5e) 

5. 

Save the measured value 

by pressing key 

 

MEM 

 (3) 

6. 

Relative measuring 

to a reference value by pressing key 

 CLR 

 (3)  

  Revert to normal measured value by pressing and holding down key

 CLR 

  

7. 

Evaluating a measuring operation  

  Call up maximum / minimum values by pressing keys 

 MAX 

 / 

 MIN 

 (3)  

    To delete max. / min. value(s) press and hold down key 

 MAX 

 or 

 MIN 

 see 

 
 

Содержание HI 1

Страница 1: ...ries 5 4 INTRODUCTION 5 4 1 Functions 5 4 2 Handling batteries rechargeable batteries correctly 5 4 3 Max and Min value 5 5 INITIAL COMMISSIONING 5 6 POWER SUPPLY 6 6 1 Battery operation and supply vo...

Страница 2: ...asuring point 2nd meas value c Unit for 2nd meas value Main field d Unit 1 st meas value e 1st meas value f Operating states LOBAT Battery voltage 3 8V REL Relative measuring 3 Operating keys ON OFF T...

Страница 3: ...he device is used for any purpose other than that for which it is intended The device is damaged by electrostatic discharge or lightning The user fails to observe and comply with the operating instruc...

Страница 4: ...high voltage Such risks may occur in the following circumstances Use of the device with an unsuitable power supply and or in conjunction with unsuitable peripheral equipment Damage caused by electrost...

Страница 5: ...pped with a patented connector system The intelligent connector offers decisive advantages when connecting sensors and peripherals because all parameters are stored in an EEPROM located on the connect...

Страница 6: ...ed values and settings are retained intact If interference e g electrostatic or a malfunction e g battery failure causes the device to behave abnormally the device can be reinitialized To activate RES...

Страница 7: ...egment digits b for depicting various measuring functions a there are also 2 arrows f for depicting the operating status Functionfield Mainfield 8 2 Keys To operate the device a keypad with 7 keys is...

Страница 8: ...as you clear the memory the current measured value will appear because measuring is continuous 8 4 Measured value memory On the HI 1 any measured value can be saved To save the measured value press ke...

Страница 9: ...s CLR Entry is completed by again pressing key ON To terminate configuration at any time press key MEM 9 Technical data Hand held uni HI 1 Art No A002067 System accuracy resolution 0 1 of measured val...

Страница 10: ...ct Safety security EN 61010 1 2001 EMC EN 61326 2006 If a product is modified in any manner not agreed with us in advance this declaration becomes void When using the sensor with an extension care mus...

Отзывы: