background image

 

Page 8 of 10 

 

J. 

MAJOR PARTS LIST FOR Dual TripleBright II 

SW Filters (2 required) 

FS-60 

LW Filters (2 required) 

FL-60

 

Lamps   -   SW 

LS-60-254

 

 

MW 

LM-60-312 

 

LW350

 

LL-60-352 

 

LW370

 

LL-60-368 

 

Ballast         (2 required) 

Workhouse WH33-120-L  

 
 
 
 

 
 

K. 

Other UV SYSTEMS products and accessories to the Dual TripleBright II 

 

 

Automatic Timer 

 

T-20 

 

Electronic timer that can control up to 10 UV lights and up to four different types (such as 
LW350, LW370, MW, or SW) of lights and also ramp up and dim incandescent lights.  
Three different outputs are standard.  Designed for the single 

TripleBright II 

and the 

Dual 

TripleBright II

, but will also work for any Instant Start or Rapid Start fluorescent type 

lights that do not require starters. 

    
Contrast and Safety Goggles 

 

GB

  

 

 

These goggles will block all ultraviolet from getting in your eyes.  A necessity for every 
collector. 

 
Replacement filters 

 

FILTERS 

 

8 sizes of replacement SW or LW filters for your other ultraviolet light assemblies.  

 
Replacement lamps (tubes) 

 

LAMPS

  

 

 

17 sizes of replacement SW, MW, LW350, or LW370 lamps for your other ultraviolet light 
assemblies.  

 
Other SW UV lights 

 

SuperBright 3

 model

 4254  

 

One of the most powerful hand-held SW UV light available.  

 
MW UV light 

 

SuperBright 3

 model

 4312 

 

One of the most powerful hand-held MW UV light available.

 

 
LW UV lights 

 

SuperBright 3

 model

 4351  

 

 

 

or 

model

 4368 

 

 

Two of the most powerful hand-held LW UV lights available.  

 
 
 

Содержание Dual TripleBright II

Страница 1: ...53 7 nm the LM 60 312 is the medium wave MW lamp and has a peak output at approximately 312 nm the LL 60 352 is the long wave LW350 lamp and has peak output at approximately 352 nm and the LL 60 368 i...

Страница 2: ...e displays For short wave it uses one or two custom made quartz lamps that are very resistant to bulb solarization For medium wave it uses one or two custom made lamps with a special erythemal also ca...

Страница 3: ...protect the Dual TripleBright II during shipping All that protective material Styrofoam peanuts or bubble pack must be removed to clear the fan opening and air exit before the light is operated Make...

Страница 4: ...Page 4 of 10 NEVER PLUG ALL THREE CORDS INTO THE SAME POWER STRIP Always make sure the yellow cord it powered on at least 20 sec before the black cord See next photo...

Страница 5: ...on the end where the power cords enter the light E COOLING FAN The Dual TripleBright II has a built in cooling fan to maintain the lamps at its most efficient operating conditions by maintaining an o...

Страница 6: ...r and measuring the actual 253 7 nm transmission When the light is not being used turn it off to reduce the filter s exposure to excessive ultraviolet Turning the light on and off frequently has no ef...

Страница 7: ...s that allow the lamps to be turned on and off millions of times without affecting the normal life of the lamps However the lamps will fail at some time usually by failing to come on A life cycle test...

Страница 8: ...I but will also work for any Instant Start or Rapid Start fluorescent type lights that do not require starters Contrast and Safety Goggles GB These goggles will block all ultraviolet from getting in y...

Страница 9: ...orescent minerals and their localities ultraviolet lamps and related matters The yearly or biennial Journal of the Fluorescent Mineral Society publishes technical articles of lasting interest FMS memb...

Страница 10: ...Page 10 of 10...

Отзывы: