3.  Place a fresh 9V battery in the compartment.

NOTE:

If you do not plan to use the meter for a month or more,

remove the battery and store it in an area that won’t be damaged by a
leaking battery.

4.  Reattach the battery compartment cover to the meter and 

reinstall the screw.

S p e c i f i c a t i o n s

M a i n t e n a n c e

Periodic service

WARNING!

Repair and service of this instrument is to be performed by qualified
personnel only. Improper repair or service could result in physical
degradation of the meter. This could alter the protection from 
electrical shock and personal injury this meter provides to the 
operator. Perform only those maintenance tasks that you are
qualified to do.

These guidelines will help you attain long and reliable service from 
your meter:

1. Calibrate your meter annually to ensure it meets original 

performance specifications.

2.  Keep your meter dry. If it gets wet, wipe it dry immediately. Liquids 

damage electronic circuits.

3.  Whenever pra c t i cal, keep the meter away from dust and dirt, which 

can cause premature wear.

4.  Although your meter is built to withstand the rigors of daily use, it 

can be damaged by severe impacts. Use reasonable caution when
using and storing the meter.

Cleaning and Decontamination

Periodically clean your meter’s case using a damp cloth. 

DO NOT

use

abrasives, cleaning solvents or strong detergents, as they may damage
the finish or affect the reliability of the structural components.

Battery Replacement

Always use a fresh replacement battery of the specified size and type.
Immediately remove the old or weak battery from the meter and dis-
pose of it in accordance with your local disposal regulations. Old or
defective batteries can leak chemicals that corrode electronic circuits.

WARNING!

To avoid electric shock, be sure to turn off the meter’s power and 
disconnect both test leads from any equipment before you remove 
or install batteries.

To install a new battery, follow these procedures:

1. Remove the screw from the battery compartment cover on the 

back of the meter and lift the cover.

2.  Remove and discard the old battery. Always dispose of old batteries 

promptly in a manner consistent with local disposal regulations.

UTL260-MAN    

P. 4

Environment conditions

Installation categories II, 600V max. to earth

Pollution degree

2

Altitude

< 2000 m

Operating temperature

0˚~40˚C (<80% RH)

Storage temperature

-10˚~60˚C (<70% RH, battery removed)

Max. Voltage between

600 V rms

terminals and earth ground
Operating principal

Dual slop integration

Sample rate

2 times/sec for digital data

Display

3-1/2 digits LCD display with max. Reading 1999
Automatic indication of functions and symbols

Range selection

Manual

Over range indication

LCD will display “

1

”. If measure value is over 

2000V the LCD will display “

1

” (AC V & DC V range)

Low battery indication

The “          “ is displayed when the battery is under 
the proper operation range

Power source

DC 3VX3, CR2032

Polarity indication

“-” displayed automatically

Jaw opening diameter

cables 28mm

Maximum conductor size

28mm

Dimensions

194 (L) x 72 (W) x 35 (H) mm

Weight

200g. Approx. (battery included)

Accessories

Manual
Test leads
Carrying case

Содержание UTL260

Страница 1: ...UTL260 INSTRUCTION MANUAL Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com ...

Страница 2: ...fully In this manual the word WARNING is used to indicate conditions or actions that may pose physical hazards to the user The word CAUTION is used to indicate conditions or actions that may damage this instrument WARNING Exceeding the specified limits of this meter is dangerous and can expose the user to serious or possibly fatal injury DO NOT attempt to measure any voltage that exceeds 600 volts...

Страница 3: ...7 DC input indication 8 AC input indication 9 Polarityindication Operating Instructions If the current under measurement is higher than the selected value for a long period overheating may take place compromising the safety and operation of inner circuits WARNING DO NOT measure currents on high voltage conductors 600V to avoid risk of discharge and or incorrect readings AC Current Measurement WARN...

Страница 4: ...00Vrms Do not attempt to take any voltage measurement that exceeds 600Vrms to avoid electrical shock hazard and or damage to the instrument 1 Set the rotary switch to the 600V range 2 Connect the black and red test leads to the COM and VΩ terminals respectively 3 Connect the test leads to the circuit being measured and read the displayed value Fig 3 Resistance Measurement WARNING Before taking any...

Страница 5: ...bility of the structural components Battery Replacement Always use a fresh replacement battery of the specified size and type Immediately remove the old or weak battery from the meter and dis pose of it in accordance with your local disposal regulations Old or defective batteries can leak chemicals that corrode electronic circuits WARNING To avoid electric shock be sure to turn off the meter s pow...

Страница 6: ...digits at 64 to 82 F 18 to 28 C with relative humidity to 80 AC Current Frequency response 50 60Hz DC Voltage Input impedance 10MΩ Maximum input voltage 600V DC or 600V AC rms AC Voltage Input impedance 10MΩ Frequency response 40 400Hz Maximum input voltage 600V DC or 600V AC rms Resistance Open circuit voltage less than 700mV Overload protection 250V DC or 250V AC rms UTL260 MAN P 5 Range Resolut...

Страница 7: ... of merchantability and fitness for a particular purpose are limited to the express warranty UEi shall not be liable for loss of use of the instrument or other incidental or consequential damages expenses or economic loss or for any claim or claims for such damage expenses or economic loss A purchase receipt or other proof of original purchase date will be required before warrantyrepairs will be r...

Отзывы: