9
20
20
20
20
Breaker Box
Pressure
gauge
Air release valve
Set to
18 psi
1 in. Discharge Tee
1
2
1
1. Completely drain all water from tank by
turning off pump and opening a faucet until
water stops.
2. Use a pressure gauge to ensure it’s set to 18
PSI.
a. Use a tire pump to adjust the PSI to 18 PSI
b. If water leaks from the air release valve,
replace the pressure tank.
CHECK TANK PRESSURE
PUMP TO TANK CONNECTION (DISCHARGE PIPE)
1. Wrap thread tape around threads of a 1 in.
discharge tee (not included). Using a pipe
wrench, thread the 1 in. discharge tee into the
1 in. opening in the top of pump (A).
A