63
12 - RATINGS AND CAPACITIES
12.3 High Altitude Ratings
12.4 High Altitude Chart
For elevations between 2000 ft (600 m) and 10,000 ft (3048 m), use the following information:
Altitude
Model
Number
Input, MBH (KW)
Heating
Capacity,
MBH*
AFUE, %
Domestic Hot Water (DHW) Circuit
**
Maximum
Minimum
Max Input,
MBH
Min
Input,
MBH
Max
Output,
MBH
Min Output,
MBH
2,000-4,500 ft
(600m-1350m)
MAHF-100
88.8
16.5
81.1
95.0
MACF-115
88.8
16.5
81.1
95.0
109.7
16.6
100.2
15.3
MAHF-125
113
22
101
95.0
MACF-150
113
22
101
95.0
137
22
122
19
MAHF-165
147
26.5
137
95.0
MACF-205
147
26.5
137
95.0
184.5
26.5
157
23
4,501-6,500 ft
(1372 m -1981
m)
MAHF-165
135
24.1
126
95.0
MACF-205
135
24.1
126
95.0
168
24.1
143
20
6,501-10,000 ft
(1982 m -3048
m)
MAHF-165
113
20.3
105
95.0
MACF-205
113
20.3
105
95.0
141
20.3
120
17
*
Max CH Supply temp 176° F (80° C) for MAHF-125 and MACF-150
*
Max DHW temp 140° F (60° C)
** MACF-150 Max DHW Flow rate 3.5 gpm (13.2 l/min)
**
-205 Max DHW flow rate 5.0 gpm (18.9 L/min)
GAS
Natural
LP
Model
Altitude
0-2,000 ft.
[0-610 m]
2,000- 10,000 ft
[610-3,048 m]
0-2,000 ft.
[0-610 m]
2,000- 10,000 ft
[610-3,048 m]
Parameter
P71
High Fire
Fan Speed
100
Setting
RPM
85
5,350
75
5,250
85
5350
75
5250
115
Setting
RPM
220
7,200
190
6,900
220
7,200
190
6,900
125
Setting
RPM
115
6150
60
5600
65
5650
40
5400
150
Setting
RPM
220
7200
170
6700
170
6700
150
6500
165
Setting
RPM
105
6050
120
6200
205
Setting
RPM
225
7250
220
7200
Parameter
P72
Low Fire
Fan Speed
100
Setting
RPM
50
1,250
70
1450
115
Setting
RPM
55
1,300
55
1,300
125
Setting
RPM
40
1150
25
1000
150
Setting
RPM
40
1150
25
1000
165
Setting
RPM
43
1180
60
1350
45
1200
60
1350
205
Setting
RPM
40
1150
60
1350
45
1200
60
1350
CO Limit < 200 ppm
240013371 REV B, [10/01/2021]
Содержание MACF-115
Страница 2: ...MACF 150 ...
Страница 4: ...MAHF 125 ...
Страница 74: ...70 A 1 MODEL 100 Heat Only APPENDIX A WIRING DIAGRAMS 240013371 REV B 10 01 2021 ...
Страница 75: ...71 A 2 MODEL 125 Heat Only APPENDIX A WIRING DIAGRAMS 240013371 REV B 10 01 2021 ...
Страница 76: ...72 APPENDIX A WIRING DIAGRAMS A 3 MODEL 165 Heat Only 240013371 REV B 10 01 2021 ...
Страница 77: ...73 APPENDIX A WIRING DIAGRAMS A 4 MODEL 115 Combi 240013371 REV B 10 01 2021 ...
Страница 78: ...74 A 5 MODEL 150 Combi APPENDIX A WIRING DIAGRAMS 240013371 REV B 10 01 2021 ...
Страница 79: ...75 A 6 MODEL 205 Combi APPENDIX A WIRING DIAGRAMS 240013371 REV B 10 01 2021 ...
Страница 80: ...76 NOTES 240013371 REV B 10 01 2021 ...
Страница 81: ...77 NOTES 240013371 REV B 10 01 2021 ...
Страница 82: ...78 NOTES 240013371 REV B 10 01 2021 ...
Страница 117: ...33 MODEL 100 Heat Only 100 HEAT ONLY WIRING DIAGRAM PN 240012875 REV C 10 01 2021 ...
Страница 118: ...34 MODEL 125 Heat Only 125 HEAT ONLY WIRING DIAGRAM PN 240012875 REV C 10 01 2021 ...
Страница 119: ...35 MODEL 165 Heat Only 165 HEAT ONLY WIRING DIAGRAM PN 240012875 REV C 10 01 2021 ...
Страница 120: ...36 115 COMBI WIRING DIAGRAM MODEL 115 Comb PN 240012875 REV C 10 01 2021 ...
Страница 121: ...37 MODEL 150 Combi 150 COMBI WIRING DIAGRAM PN 240012875 REV C 10 01 2021 ...
Страница 122: ...38 MODEL 205 Combi 205 COMBI WIRING DIAGRAM PN 240012875 REV C 10 01 2021 ...
Страница 127: ...43 LOW WATER CUTOFF DETAIL LOW WATER CUTOFF NO NO YES PN 240012875 REV C 10 01 2021 ...
Страница 132: ...48 3 FAULT SOLUTION SECTIONS PN 240012875 REV C 10 01 2021 ...
Страница 135: ...51 Parameter ID Changed From Changed To Date Reason PARAMETER CHANGE HISTORY PN 240012875 REV C 10 01 2021 ...