background image

Page 8/21 

UTEK TECHNOLOGY (ASIA) CO., Ltd.

 

http://www.szutek.com

 0755-27886063 

b

Product Configuration Table (for one set of equipment) 

 

Configuration 

 

 

Model 

Serial server host 

Power supply 

adapter 

Software 

Product manual and 

warranty sheet 

UT-6602M-I(2 channels of 

RS485/422) 

1 1 

DC5V/2A 1 

UT-6604M-I(4 channels of 

RS485/422) 

1 AC220V 

cable 1 

UT-6608M-I(8 channels of 

RS485/422) 

1 AC220V 

cable 1 

UT-6616M-I(16 channels of 

RS485/422) 

1 AC220V 

cable 1 

 

 

Chapter Four: Description of WEB operation of    UT-66XXM-I series serial server 

a) Server 

Menu 

Server Menu--Server Information (setting of server information) 

Server Name 

Serial server name. 

Server Position 

Serial server position (can be user-defined (such as name of the installation position) for 

convenient maintenance). 

Ethernet IP Address 

Serial server internal IP address 

Ethernet IP Mask 

Internal network subnet mask . 

Ethernet Mode 

Network rate can be manually set to 10M or 100M, the default option is auto - detecting the 

network rate automatically. 

DHCP Enabled 

Enables the automatic IP configuration. 

DHCP CLIENT ID 

If the Ethernet is to be used as the DHCP client, then this option is to be input to the CLIENT ID 

of the DHCP (in hexadecimal format) . 

Default Gateway 

Gateway 

Primate DNS Server 

The primary DNS server. 

Second DNS Server 

The secondary DNS server. 

CONSOLE Timeout 

Console time out (access the serial server via the console port) 

Boot Host 

Extension option (starting the host) 

Boot File 

Extension option (import files) 

Submit 

Submit (the above options of the serial ports must be submitted to complete the settings) 

 

 

 

 

 

 

 

 

 

Содержание UT-6602M-I

Страница 1: ...0 d Authority Management 16 e System Stats 16 f Miscellaneous 16 Chapter 5 Troubleshooting of UT 66XXM I series serial server 16 a Can t find the IP address of the serial server after running upgrad exe 16 b Unable to open a serial port 17 c Can t receive send data 17 d Forget the password previously set 17 e Lousy code received sent 17 f The serial communication server is used as the dialing serv...

Страница 2: ... SOCKET UDP Full English interface for all programs wizards are easy to use even for new computer users UT 66XXM I series serial server includes the following models b Main features Hardware features English menus of configuration interface with the various operation modes able to meet the application demand of different industries Virtual COM drive software for Windows Flexible and reasonable Fix...

Страница 3: ...er won t be affected by other accidental actions In addition any name started with tty can be assigned to each login terminal by the user under the fixed port mode which is more convenient for management and easier for troubleshooting Supports PPP serial mode All the ports of the UT 66XXM I series serial server support the PPP protocol and can be used other as a PPP server end or as a client end a...

Страница 4: ...UT 66XXM I series serial server is connected to network during operation the server is PPP certified support PAP and CHAP certification to ensure the security of the server during the network access Possible to pose limits to the hosts or network segments allowed to access the server the unauthorized objects not registered in the hosts list and the network segment will not be able to pass the netw...

Страница 5: ...s Sequence Model First Second Third Fourth Fifth UT 6602M I 10 100M Network connection Power 1 indicator for serial port status 2 indicators for serial port statuses UT 6604M I 10 100M Network connection Power UT 6608M I 10 100M Network connection Power UT 6616M I Power Network connection 10 100M Network full half duplex indicator c Definition of pins 1 Definition of serial pins for UT 6602M I RJ4...

Страница 6: ...finition of the UT 6616M I serial pins RJ45 RJ45 RS 232 RS 485 HALF RS 485 FULL RS 422 1 TxD DATA TxD TxD 2 RxD DATA TxD TxD 3 RTS RxD RxD 4 CTS RxD RxD 5 DSR 6 GND GND GND GND 7 DTR 8 DCD RJ4 5 RS 232 RS 485 HALF RS 485 FULL RS 422 1 TxD RxD 1 RxD 1 2 RxD TxD 2 TxD 2 3 RTS RxD 3 RxD 3 4 CTS TxD 4 TxD 4 5 DSR 6 GND GND 6 7 DTR 8 DCD ...

Страница 7: ...ype RJ45 Protection 15KV lightning protection Signal RS232 DCD RxD TxD DTR GND DSR RTS CTS RS422 TXD RXD TXD RXD GND RS485 Data Data Network port Rate 10 100M self adaptive support manual configuration Type RJ45 Protection 3KV built in electromagnetic insulation Software Protocol ARP IP ICMP UDP TCP PPP HTTP TELNET DNS DHCP PAP CHAP Virtual COM Windows NT 2000 XP Environment Operating Temperature ...

Страница 8: ...er defined such as name of the installation position for convenient maintenance Ethernet IP Address Serial server internal IP address Ethernet IP Mask Internal network subnet mask Ethernet Mode Network rate can be manually set to 10M or 100M the default option is auto detecting the network rate automatically DHCP Enabled Enables the automatic IP configuration DHCP CLIENT ID If the Ethernet is to b...

Страница 9: ...t in first out enabled for default Lock Locking configuration possible to lock the configuration of the port for the convenient repeated setting in future days tXON tXOFF TX Empty Del String RX Freetime RX idle time RX Max Length RX maximum length TX Block Time TX block time XANY DTR ON DTR is a hardware based control mode of flow control where you can decide if it is necessary to set a data termi...

Страница 10: ...ng of the serial devices more flexible and more convenient In addition the multiple connections resource can be used as a connection backup Communication Mode Operation mode option Sessions Number of hosts connected to the device up to six Authentication Authentication Submit Submit the above options of the serial ports must be submitted to complete the settings Apply to all ports Apply to all por...

Страница 11: ...thernet cr lf means that the server will change an ENTER received from a serial port to an ENTER and a NEW LINE and then send them to the Ethernet Sessions Number of hosts connected to the device up to six Strip NULL Authentication It is possible that the server send a request for authentication when connected the connection will be cancelled if the user s name and the password are incorrect This ...

Страница 12: ...terminal for each time thus the terminal name is fixed Communication Mode Operation mode Screens Number of screens each serial port supports up to 6 screens UT 66XXM I supports multi screen switching Term Type Terminal type Here the user can enter the type of the terminal simulation to adapt to the handling of special characters Auto Connect Automatic connection There are two options cr and auto c...

Страница 13: ... 3 Phone Number4 Telephone number 4 Callback To call back Callback Phone The callback telephone number PPP dialout In this mode each serial port of the server can be used as the dial in out end of the PPP server it supports applications of remote dialing access Communication Mode Operation mode Peer IP The IP address of the peer Used as the IP address of the peer serial port after the connection b...

Страница 14: ...odem dialing command What dialing mode the MODEM will use audio or pulse Type atdt for audio dialing which is the most case in practical applications and atdp for pulse dialing Phone Number1 Dialing out number 1 Phone Number2 Dialing out number 2 Phone Number3 Dialing out number 3 Phone Number4 Dialing out number 4 CallBack To callback CallBack Phone The callback telephone number Dynamic Dial Dyna...

Страница 15: ...re printing the main text End Sequeue End printing sequence The string sent by the server to the printer after the printing of the main text is finished CR As There are four parameters none cr lf and cr lf none means that the server will not send an ENTER received from a serial port to the Ethernet cr means that the server will send an ENTER received from a serial port to the Ethernet just as it i...

Страница 16: ...tion UDP socket information f Miscellaneous Route Table Routing list Host Table Hosts list EA LAN1 Users Select ports to reset Selection of serial port reset Save Configurations It s very important to save the settings Any modification to the WEB need to be saved before exiting the web page otherwise the settings will be restored Reboot Server Restart the server Chapter Five Troubleshooting of UT ...

Страница 17: ...be noticed for our 485 devices 2 Check if the cable length exceeds the standard distance and the cable quality increasing the transceiver or the optical shutter is also applicable 3 Make sure the baudrate set matches with the bottom end device 4 Find out if it is possible to receive normal data using network or serial port commissioning assistant without upper end software If can the problem might...

Страница 18: ...art the attached software upgrade as show in the figure below select Server search all devices or click on the red circle in the following figure and then you can view IP addresses and basic information of all the UT 66XXM I series devices connected to the network Click and select a device change the IP address through selecting Tool Temporary change ip address The IP address should be in the same...

Страница 19: ...port over TCP IP window pops up click Next to go to the next step 3 In this window you will be noted about where the virtual serial port software is installed Click Next to go to the next step 4 The prompt indicates that the installation is to be started Click Install to go to the next step ...

Страница 20: ...Port setting will pop up enter the IP address of the serial server such as 192 168 1 247 Enter 1 for Device port note that based on what port the multi port serial server is entered e g enter 5 for the fifth port of an 8 port serial server and you can also create 8 serial ports at the same time when you just enter 1 8 KeepAlive is the active time of the port and the typical setting is 300s Status ...

Страница 21: ...Page 21 21 UTEK TECHNOLOGY ASIA CO Ltd http www szutek com 0755 27886063 ...

Отзывы: