DRAFT

3.4.2. Leave the designated slave unit in its current condition and go to the other end of the 

locomotive consist to set up the master unit.

3.5. Setup - Master Unit

3.5.1.Set up a second MU Cable Tester unit to be used as the master.

A. Remove the cover. 

B. Power switch is off.

C. Confirm emergency shut off switch to be in home position (button up).

D.  Select power source: internal battery or apply AC adapter.

3.5.2.Locate the Chassis Test Lead from the storage pouch

A. Connect it to the threaded chassis post next to the MU receptacle. The forked terminal 

must be securely sandwiched between the threaded nut and threaded post plate. 

B. Clip the other end of the chassis test lead to the locomotive chassis.

3.6. Self test - Master Unit

3.6.1. Turn Power switch of master unit to ON position; wait for unit to completely boot up. 

3.6.2. Display shows “MU Cable Tester.” Press F1 to set test unit to Master.

A. View the display to confirm “Master Unit” designation.

3.6.3. Press F1 to Start the Self-test sequence.

3.6.4. Wait for the designated master unit to complete self test.

A. When unit displays “Self Test Pass,” proceed to step 3.6.5.

B. If self test fails, resolve source of failure and retest. Indications found on the Display can 

be used to help determine cause of failure.

3.6.5.Connect the Master unit to the locomotive consist by inserting an MU jumper cable into the 

master MU cable receptacle and the other end into the open end of the consist MU receptacle.

3.6.6.If a specific test is required, press F2 Select

A. Use the Prev (F1) and Next (F3) buttons to navigate to the desired test.

B. Press Select (F2) to select the test.

3.6.7.The entire test or a subset of the selected test may be selected.

A. If the entire test is required, press Select (F2) for the All Tests selection.

B. Use the Prev (F1) and Next (F3) buttons to navigate to the other test options.  Then press 

Select (F2) for the desired option.

3.6.8. From the “Self Test Pass” menu, note that Shorts test will begin automatically at 5 seconds 

after pressing F3. Press F3 now to continue to Shorts Test menu.

16814-99 Rev. A

Содержание 16814-00

Страница 1: ... OPERATIONS MANUAL for MU CABLE TESTER MODEL NUMBER 16814 00 CAUTION All operators are expected to read and become thoroughly familiar with the entire contents of this manual before attempting to operate the MU Cable Tester ...

Страница 2: ...2 D R A DOCUMENT NO 16814 99 16814 99 Rev A ...

Страница 3: ...er Unit 5 Battery Charger Power Adapter 5 OPERATION 5 Setup Slave Unit 5 The internal battery can be used if no AC power is available Make sure the battery is sufficiently charged to be able to complete the desired MU testing 6 Startup Slave Unit Auto Testing 6 SPECIFICATIONS 8 Physical 8 Size 8 Electrical 8 Environmental 9 16814 99 Rev A ...

Страница 4: ...n freight locomotives The test operator selects one test unit to be used as a slave and the other as a master Typical equipment configuration for the MU Cable Tester System is one designated Slave unit connected to one designated Master unit by way of one MU jumper cable Up to eight railcars can be added between the slave and master units with nine jumper cables connecting the entire chain All MU ...

Страница 5: ...is available for any given test option at any given stage of the testing process LEDs provide status indication of power ON and battery charging status The emergency shut off switch provides an instantaneous disconnect of all testing signals and controls to the MU railcar lines and MU jumper cables should unsafe conditions occur for any reason Note that the emergency shut off switch does not remov...

Страница 6: ...om the Slave Unit menu Press F1 to Start the Self test sequence 3 3 2 Wait for designated slave unit to complete self test A When unit displays Self Test Pass proceed to step 3 3 3 B If self test fails resolve source of failure and retest Indications found on the display can be used to help determine cause of failure 3 3 3 Connect one end of an MU Jumper Cable to the MU socket on the designated Sl...

Страница 7: ...Master Unit designation 3 6 3 Press F1 to Start the Self test sequence 3 6 4 Wait for the designated master unit to complete self test A When unit displays Self Test Pass proceed to step 3 6 5 B If self test fails resolve source of failure and retest Indications found on the Display can be used to help determine cause of failure 3 6 5 Connect the Master unit to the locomotive consist by inserting ...

Страница 8: ...ish A If Continuity Test Fail is displayed press F2 to review the faults Follow the displayed menu options to review each fault or return to retest B When Continuity Test Pass is displayed press F3 to continue to Test Complete menu 3 9 2 Press F3 to exit or F1 to continue to the Main menu 4 Specifications 4 1 Physical 4 1 1 Size The MU Cable Tester System in comprised of two tester units each hous...

Страница 9: ...mp 4 2 2 Battery Operating Time A 5 hours with fully charged battery 4 3 Environmental The MU Cable Tester meets the following environmental specifications 4 3 1 Storage Temperature A Storage Temperature Range 40 C to 85 C 4 3 2 Operating Temperature A Operating Temperature Range 0 C to 70 C 16814 99 Rev A ...

Отзывы: